Metraipolis › archive › dc_2cecc733f58f
EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate — arXiv:2610.32674
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.32674
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-26T20:08:26.576Z
- SHA-256 of the archived text
a4d36b0bcc465a87534e571df03f80c4410563c96b5f8f22c7cef973baa6e2b0- Stable URL of this page
https://metraipolis.com/documento/dc_2cecc733f58f
How to cite
EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate — arXiv:2610.32674 — arXiv (en), https://arxiv.org/abs/2610.32674 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2cecc733f58f (Metraipolis archive dc_2cecc733f58f, sha256 a4d36b0bcc465a87534e571df03f80c4410563c96b5f8f22c7cef973baa6e2b0)
BibTeX
@misc{dc2cecc733f58f,
title = {EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate — arXiv:2610.32674},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.32674},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2cecc733f58f; sha256 a4d36b0bcc465a87534e571df03f80c4410563c96b5f8f22c7cef973baa6e2b0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.32674. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.HC, nuovi lavori del giorno). Categorie arXiv: Signal Processing (eess.SP) ; Human-Computer Interaction (cs.HC); Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2610.32674 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-26T19:48:48.365Z dalla pagina https://arxiv.org/list/cs.HC/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).