Metraipolis › archive › dc_2c35f31ecfc4

COMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory Panels — arXiv:2611.09102

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.09102
License (as archived)
CC0-1.0
Archived
2026-11-09T22:41:26.789Z
SHA-256 of the archived text
26be4e7aabcf423a20f2c96657cc08f97d4d77b9f9085250439b7b53276c9043
Stable URL of this page
https://metraipolis.com/documento/dc_2c35f31ecfc4

How to cite

COMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory Panels — arXiv:2611.09102 — arXiv (en), https://arxiv.org/abs/2611.09102 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2c35f31ecfc4 (Metraipolis archive dc_2c35f31ecfc4, sha256 26be4e7aabcf423a20f2c96657cc08f97d4d77b9f9085250439b7b53276c9043)
BibTeX
@misc{dc2c35f31ecfc4,
  title = {COMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory Panels — arXiv:2611.09102},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.09102},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2c35f31ecfc4; sha256 26be4e7aabcf423a20f2c96657cc08f97d4d77b9f9085250439b7b53276c9043},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.09102. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Machine-learning models based on routine laboratory panels can predict outcomes but can be difficult to interpret and operationalize. We present COMBIO, an automated pipeline that distils such a model into a compact closed-form biomarker. The composite is a product of laboratory measurements raised to integer powers from minus two to two. The sign of each exponent indicates whether higher values of the corresponding measurement increase or decrease the composite. Shapley additive explanation values from the gradient-boosted reference model rank five candidate measurements and guide eligible exponent signs. An exhaustive search over small integer exponents selects the formula on an inner validation set, before evaluation on the reserved test set. We evaluated COMBIO across six tasks: three National Health and Nutrition Examination Survey outcomes, liver-disease classification in the Indian Liver Patient Dataset, and Medical Information Mart for Intensive Care IV in-hospital mortality and sepsis case-finding, with external evaluation in the eICU Collaborative Research Database for the two hospital tasks. Across the six test sets, COMBIO's area under the receiver operating characteristic curve differed by at most 0.03 from logistic regression using the five candidate laboratory measurements. The hospital mortality composite had an area under the curve of 0.698 in the external database. A version restricted to widely available measurements in the source hospital database achieved an area under the curve of 0.786 in a cohort covering 92% of admissions. The multiplicative representation provides compactness rather than additional accuracy, and local validation and recalibration are required before clinical use.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2611.09102 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-09T22:33:47.152Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).