Metraipolis › archive › dc_2b5c809c7dfb

Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift — arXiv:2610.39704

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.39704
License (as archived)
CC0-1.0
Archived
2026-11-01T02:31:19.844Z
SHA-256 of the archived text
7d5b8229ff6e34cb8d6d7bd8eff64a32572a3f41c22261809d8c778946a01e77
Stable URL of this page
https://metraipolis.com/documento/dc_2b5c809c7dfb

How to cite

Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift — arXiv:2610.39704 — arXiv (en), https://arxiv.org/abs/2610.39704 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2b5c809c7dfb (Metraipolis archive dc_2b5c809c7dfb, sha256 7d5b8229ff6e34cb8d6d7bd8eff64a32572a3f41c22261809d8c778946a01e77)
BibTeX
@misc{dc2b5c809c7dfb,
  title = {Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift — arXiv:2610.39704},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.39704},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2b5c809c7dfb; sha256 7d5b8229ff6e34cb8d6d7bd8eff64a32572a3f41c22261809d8c778946a01e77},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39704. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Video-based gait assessment often keeps only high-confidence pose observations, which can lower measurement error but change the movement assessed. We compared confidence selection with budget-matched random selection in a Parkinson-related cohort (n = 96) and an NF2-related replication cohort (n = 18). In the Parkinson-related cohort, confidence selection produced a small but consistent shift in the observed movement summary (+0.05 SD, 95% CI 0.03 to 0.07), while held-out Mini-BESTest error stayed flat (-0.04 points, -0.13 to 0.05); a policy preserving motion-group proportions reduced the shift, while NF2 showed no shift and its predictor did not beat a constant baseline. Because this shift mixes measurement error with selection shift, we decompose and simulate both on the cohort's window structure. Filtering lowers local error when error depends on confidence, but biases the endpoint once confidence tracks movement more than error. In the Parkinson-related data, confidence was only weakly tied to movement (rho = 0.14). There, filtering is harmless if well-tracked windows are unbiased. If instead systematic error only redistributes within participants, filtering can add up to 0.58 degrees. Unchanged clinical error from such small-cohort predictors therefore cannot show that quality filtering preserves the assessed movement.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv stat.ME, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Quantitative Methods (q-bio.QM); Methodology (stat.ME).
Pagina del lavoro: https://arxiv.org/abs/2610.39704 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:13:43.997Z dalla pagina https://arxiv.org/list/stat.ME/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).