Metraipolis › archive › dc_29ed19feeed5
Feature extraction for LSTM-based finger-joint angle estimation from sEMG — arXiv:2611.02736
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.02736
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:22:53.259Z
- SHA-256 of the archived text
6ef8c366bca82be6f824c006da52da43b3283ddde63f3dac1e500c4372ae7201- Stable URL of this page
https://metraipolis.com/documento/dc_29ed19feeed5
How to cite
Feature extraction for LSTM-based finger-joint angle estimation from sEMG — arXiv:2611.02736 — arXiv (en), https://arxiv.org/abs/2611.02736 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_29ed19feeed5 (Metraipolis archive dc_29ed19feeed5, sha256 6ef8c366bca82be6f824c006da52da43b3283ddde63f3dac1e500c4372ae7201)
BibTeX
@misc{dc29ed19feeed5,
title = {Feature extraction for LSTM-based finger-joint angle estimation from sEMG — arXiv:2611.02736},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.02736},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_29ed19feeed5; sha256 6ef8c366bca82be6f824c006da52da43b3283ddde63f3dac1e500c4372ae7201},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.02736. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2611.02736 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T11:02:37.635Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).