Metraipolis › archive › dc_298cd7558f9b
An MRI-Guided Robotic System to Improve Hippocampal Access for Epilepsy Interventions — arXiv:2609.13572
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.13572
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T02:09:25.977Z
- SHA-256 of the archived text
30b354a22b405146e41ef52d41729fa8ac94f2c8ca09b0c009e2a9789f345fa6- Stable URL of this page
https://metraipolis.com/documento/dc_298cd7558f9b
How to cite
An MRI-Guided Robotic System to Improve Hippocampal Access for Epilepsy Interventions — arXiv:2609.13572 — arXiv (en), https://arxiv.org/abs/2609.13572 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_298cd7558f9b (Metraipolis archive dc_298cd7558f9b, sha256 30b354a22b405146e41ef52d41729fa8ac94f2c8ca09b0c009e2a9789f345fa6)
BibTeX
@misc{dc298cd7558f9b,
title = {An MRI-Guided Robotic System to Improve Hippocampal Access for Epilepsy Interventions — arXiv:2609.13572},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.13572},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_298cd7558f9b; sha256 30b354a22b405146e41ef52d41729fa8ac94f2c8ca09b0c009e2a9789f345fa6},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.13572. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This paper presents an MRI-guided robotic system that improves hippocampal access by delivering a curved needle-like laser ablator through the foramen ovale, a natural opening in the base of the skull. Both the delivery path and the curved nature of the needle improve upon current clinical straight-line laser interstitial thermal therapy (LITT) as measured by hippocampal cannulation percentage. We describe the design of the robotic system which includes positioning, aiming, and curved needle deployment stages, followed by experimental results assessing cannulation percentages using MRI images in phantoms. In three curvilinear, single-insertion experiments, we achieved cannulation percentages of 93.5%, 96.5%, and 60.4%, exceeding reported clinical averages of 50-60%. Seizure control is believed by physicians to be a function of hippocampal volume treated, and our system provides a means of treating a greater volume of the hippocampus with LITT-based interventions. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-15 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.13572 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T01:52:32.295Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).