Metraipolis › archive › dc_26cf690a1713

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images — arXiv:2608.29348

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.29348
License (as archived)
CC0-1.0
Archived
2026-10-17T07:44:15.066Z
SHA-256 of the archived text
5b67a7700150e991e9d41a5ce506e8a53fa58f36e862ae7faab2cb76ba032782
Stable URL of this page
https://metraipolis.com/documento/dc_26cf690a1713

How to cite

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images — arXiv:2608.29348 — arXiv (en), https://arxiv.org/abs/2608.29348 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_26cf690a1713 (Metraipolis archive dc_26cf690a1713, sha256 5b67a7700150e991e9d41a5ce506e8a53fa58f36e862ae7faab2cb76ba032782)
BibTeX
@misc{dc26cf690a1713,
  title = {Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images — arXiv:2608.29348},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.29348},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_26cf690a1713; sha256 5b67a7700150e991e9d41a5ce506e8a53fa58f36e862ae7faab2cb76ba032782},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.29348. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: this https URL

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.29348 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T07:28:26.541Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).