Metraipolis › archive › dc_250fa159712a
BioSync: Transformer-Based Cross-Modal Fusion for a Multimodal Physiological Digital Biomarker — arXiv:2609.04504
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.04504
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T22:18:41.423Z
- SHA-256 of the archived text
cd2026425e01676e605cc64fab1cef19752334cc919416c50a0a220c355a5d71- Stable URL of this page
https://metraipolis.com/documento/dc_250fa159712a
How to cite
BioSync: Transformer-Based Cross-Modal Fusion for a Multimodal Physiological Digital Biomarker — arXiv:2609.04504 — arXiv (en), https://arxiv.org/abs/2609.04504 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_250fa159712a (Metraipolis archive dc_250fa159712a, sha256 cd2026425e01676e605cc64fab1cef19752334cc919416c50a0a220c355a5d71)
BibTeX
@misc{dc250fa159712a,
title = {BioSync: Transformer-Based Cross-Modal Fusion for a Multimodal Physiological Digital Biomarker — arXiv:2609.04504},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.04504},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_250fa159712a; sha256 cd2026425e01676e605cc64fab1cef19752334cc919416c50a0a220c355a5d71},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04504. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cardiac, neural, behavioral, and speech measurements from wearable and mobile devices provide partial, noise-sensitive views of physiological state. BioSync combines these measurements into the \textbf{BioSync Index (BSI)}, a continuous composite digital biomarker defined under the BEST framework. The model applies multi-head self-attention to modality tokens and adds a linear branch whose hypothesis class includes standard feature concatenation. This architecture is motivated by latent-variable measurement theory and by the possibility that joint observations contain information unavailable from individual modalities. We evaluated BioSync on two literature-informed synthetic cohorts: a four-modality cognitive-decline cohort using HRV, EEG, actigraphy, and speech, and a metabolic-autonomic cohort structured around the public AI-READI wearable schema. In the cognitive cohort, BioSync and concatenation obtained AUCs of 0.928 and 0.926, respectively. In the metabolic cohort, BioSync obtained accuracy/F1 of 0.764/0.766, compared with 0.756/0.758 for concatenation. The BSI correlated with latent severity in both cohorts ($r=0.91$ and $r=0.68$). A pure-attention ablation obtained cognitive-cohort AUC 0.911, locating the increase to 0.928 in the combined wide-and-deep architecture. With matched modality-dropout training, BioSync led concatenation at five of six cognitive-cohort corruption rates and at the highest metabolic-cohort rate. Its cognitive-cohort AUC was also higher than five published digital-biomarker reference values, although differences in datasets and tasks preclude a controlled benchmark claim. Comparison with single-modality, early-fusion, and late-fusion designs across six prespecified criteria identifies the model's computational properties; validation on real cohorts remains necessary.
Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-07 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI) ; Information Retrieval (cs.IR).
Pagina del lavoro: https://arxiv.org/abs/2609.04504 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T22:18:11.353Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).