Metraipolis › archive › dc_24a22310fa64
Manifold Fitting by Successive Tangent-Space Projection — arXiv:2610.09423
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.09423
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T12:40:05.872Z
- SHA-256 of the archived text
6f9670438bc3664195e36e950378628ded555085b5fc0fe6a421632f226ac082- Stable URL of this page
https://metraipolis.com/documento/dc_24a22310fa64
How to cite
Manifold Fitting by Successive Tangent-Space Projection — arXiv:2610.09423 — arXiv (en), https://arxiv.org/abs/2610.09423 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_24a22310fa64 (Metraipolis archive dc_24a22310fa64, sha256 6f9670438bc3664195e36e950378628ded555085b5fc0fe6a421632f226ac082)
BibTeX
@misc{dc24a22310fa64,
title = {Manifold Fitting by Successive Tangent-Space Projection — arXiv:2610.09423},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.09423},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_24a22310fa64; sha256 6f9670438bc3664195e36e950378628ded555085b5fc0fe6a421632f226ac082},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.09423. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Manifold fitting seeks to recover the geometric structure underlying noisy ambient observations. We propose Successive Tangent Space Projection (STSP), an iterative manifold-fitting method that reduces normal noise while preserving tangential variation. The former improves fitting accuracy, whereas the latter helps retain geometric coverage. We characterise the \rev{nearby population fixed-point set} of STSP as a manifold-fitting object. Under uniform sampling from a compact smooth manifold with positive reach and isotropic Gaussian noise, this set lies within $O(\sigma^2)$ of the underlying manifold, and \rev{nearby population orbits} converge geometrically to it. At the finite-sample level, with high probability, fixed points in the local tube lie within $O(\sigma^2)$ of the underlying manifold up to sampling error, and empirical orbits \rev{initialised within that tube} and generated from a fixed reference sample enter and remain in the same neighbourhood. We further develop a multi-scale extension, MS-STSP, designed to reduce curvature bias while preserving the $O(\sigma^2)$ geometric localization order of STSP at both the population and finite-sample levels. Numerical experiments show that STSP compares favourably with competing methods in balancing fitting accuracy and geometric coverage, and that MS-STSP reduces curvature-induced shrinkage, particularly under high noise.
Tema degli esploratori: statistica e scienza dei dati (elenco arXiv stat.ME, nuovi lavori del giorno).
Categorie arXiv: Methodology (stat.ME).
Pagina del lavoro: https://arxiv.org/abs/2610.09423 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:15:15.321Z dalla pagina https://arxiv.org/list/stat.ME/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).