Metraipolis › archive › dc_248d62ce2650
SimCortex v2: Joint Cortical Surface Reconstruction with Near-Zero Collisions and Self-Intersections — arXiv:2610.07378
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.07378
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T13:07:06.706Z
- SHA-256 of the archived text
7c07bfe7b9b77bb3a2ef551a8c39369deebb7362a9c8fa475a45f1893869430d- Stable URL of this page
https://metraipolis.com/documento/dc_248d62ce2650
How to cite
SimCortex v2: Joint Cortical Surface Reconstruction with Near-Zero Collisions and Self-Intersections — arXiv:2610.07378 — arXiv (en), https://arxiv.org/abs/2610.07378 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_248d62ce2650 (Metraipolis archive dc_248d62ce2650, sha256 7c07bfe7b9b77bb3a2ef551a8c39369deebb7362a9c8fa475a45f1893869430d)
BibTeX
@misc{dc248d62ce2650,
title = {SimCortex v2: Joint Cortical Surface Reconstruction with Near-Zero Collisions and Self-Intersections — arXiv:2610.07378},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.07378},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_248d62ce2650; sha256 7c07bfe7b9b77bb3a2ef551a8c39369deebb7362a9c8fa475a45f1893869430d},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.07378. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Reconstructing cortical WM and pial surfaces from structural magnetic resonance imaging (MRI) is a prerequisite for surface-based neuroanatomical analysis, yet remains challenging because the cortex is thin and tightly folded. Reconstruction methods can produce geometric artifacts such as mesh self-intersections and collisions between cortical surfaces, and although recent deep learning methods have reduced reconstruction time from hours to minutes, these artifacts persist. We propose SimCortex v2, a deep learning framework for simultaneous reconstruction of the left and right WM and pial surfaces from T1-weighted MRI. SimCortex v2 estimates topologically correct initial surfaces from a volumetric segmentation and refines all four jointly using multi-scale stationary velocity fields predicted by a ribbon-conditioned, U-Net-like network. We evaluated SimCortex v2 on 560 cases from 14 cohorts, thirteen of them unseen during training, spanning ages 6-89, healthy and clinical populations, and scanners from three vendors. SimCortex v2 matched the surface-distance accuracy of the strongest baseline (average symmetric surface distance 0.253 mm) while showing no detected inter-surface collision in 92.14% of cases and the lowest self-intersection fraction (0.044%) among learning-based methods, whereas every baseline produced at least one collision in every case. Source code, configuration files, pretrained weights, preprocessed data, and the exact evaluation splits are publicly released. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2610.07378 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T12:37:32.879Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).