Metraipolis › archive › dc_244b29b1c494
SESO-ISAC: Service-Aware End-to-End Sensing Orchestration for 6G ISAC — arXiv:2609.06089
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.06089
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T14:09:21.257Z
- SHA-256 of the archived text
c1f1620fee0cebe73da40dde6267357907516173485fa1617a2696de08b44997- Stable URL of this page
https://metraipolis.com/documento/dc_244b29b1c494
How to cite
SESO-ISAC: Service-Aware End-to-End Sensing Orchestration for 6G ISAC — arXiv:2609.06089 — arXiv (en), https://arxiv.org/abs/2609.06089 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_244b29b1c494 (Metraipolis archive dc_244b29b1c494, sha256 c1f1620fee0cebe73da40dde6267357907516173485fa1617a2696de08b44997)
BibTeX
@misc{dc244b29b1c494,
title = {SESO-ISAC: Service-Aware End-to-End Sensing Orchestration for 6G ISAC — arXiv:2609.06089},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.06089},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_244b29b1c494; sha256 c1f1620fee0cebe73da40dde6267357907516173485fa1617a2696de08b44997},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.06089. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Unlike conventional communication services, 6G Integrated Sensing and Communication (ISAC) services require complete end-to-end sensing operations, from data collection to processing, result generation, and exposure. In this article, we propose SESO-ISAC, a service-aware end-to-end sensing orchestration framework that maps a sensing service request to a complete sensing configuration under the sensing execution context. Rather than treating sensing configuration decisions independently, SESO-ISAC captures their interdependence across the end-to-end sensing operation, evaluates candidate configurations according to the applicable QoS requirements, and re- evaluates the selected configuration as the sensing execution context changes. Through two representative case studies, we show that the preferred sensing configuration depends on the overall performance across the applicable QoS dimensions and can change during operation. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-09 in cs.NI). Categorie arXiv: Networking and Internet Architecture (cs.NI). Pagina del lavoro: https://arxiv.org/abs/2609.06089 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T13:58:54.223Z dalla pagina https://arxiv.org/catchup/cs.NI/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).