Metraipolis › archive › dc_23ddf4084239

Optimal Allocation of Grid-Forming Frequency Shaping Control — arXiv:2609.24583

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.24583
License (as archived)
CC0-1.0
Archived
2026-10-10T00:55:34.283Z
SHA-256 of the archived text
19f4f30794b65f5770e5c0d15d14ea54e96cbf08f9f75c5b72fbe8915edb7a77
Stable URL of this page
https://metraipolis.com/documento/dc_23ddf4084239

How to cite

Optimal Allocation of Grid-Forming Frequency Shaping Control — arXiv:2609.24583 — arXiv (en), https://arxiv.org/abs/2609.24583 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_23ddf4084239 (Metraipolis archive dc_23ddf4084239, sha256 19f4f30794b65f5770e5c0d15d14ea54e96cbf08f9f75c5b72fbe8915edb7a77)
BibTeX
@misc{dc23ddf4084239,
  title = {Optimal Allocation of Grid-Forming Frequency Shaping Control — arXiv:2609.24583},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.24583},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_23ddf4084239; sha256 19f4f30794b65f5770e5c0d15d14ea54e96cbf08f9f75c5b72fbe8915edb7a77},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.24583. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Various inverter-based control strategies have been proposed to improve frequency security for power systems with high renewable penetration. Among them, the grid-forming frequency shaping control is particularly promising due to its ability to shape the post-contingency aggregate system frequency dynamics into first-order with prescribed rate of change of frequency (RoCoF) and steady-state frequency deviation. Moreover, the shaped aggregate dynamics depends on the harmonic sum of all inverter transfer functions rather than on their distribution. In light of this, here we explore how to allocate shaping control resources to minimize the transient control effort needed to achieve ideal coherent dynamics. We formulate it as a constrained optimization problem by tackling two main difficulties. First, we make the squared $\mathcal{H}_2$ norm legitimate quantification of transient control cost under step power imbalances through a system transformation. Second, we simplify the $s$-domain constraint for Nadir elimination into a standard constraint that is easy to implement in optimization. The resulting non-convex optimization problem can be solved by existing successive convexification method. The effectiveness of the allocation has been verified on the modified Icelandic Power Network test case.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-22 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.24583 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T23:57:37.641Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).