Metraipolis › archive › dc_227ff1fc3911

Sliding Mode Control of Cardiac Rhythms in the Sinoatrial Node using Gaussian Process Regression — arXiv:2609.18116

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.18116
License (as archived)
CC0-1.0
Archived
2026-10-15T18:22:35.939Z
SHA-256 of the archived text
887ca8c609f77227fd43dfb6f4dda75f5afc23178222c8dfd4f640e1f88ee355
Stable URL of this page
https://metraipolis.com/documento/dc_227ff1fc3911

How to cite

Sliding Mode Control of Cardiac Rhythms in the Sinoatrial Node using Gaussian Process Regression — arXiv:2609.18116 — arXiv (en), https://arxiv.org/abs/2609.18116 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_227ff1fc3911 (Metraipolis archive dc_227ff1fc3911, sha256 887ca8c609f77227fd43dfb6f4dda75f5afc23178222c8dfd4f640e1f88ee355)
BibTeX
@misc{dc227ff1fc3911,
  title = {Sliding Mode Control of Cardiac Rhythms in the Sinoatrial Node using Gaussian Process Regression — arXiv:2609.18116},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.18116},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_227ff1fc3911; sha256 887ca8c609f77227fd43dfb6f4dda75f5afc23178222c8dfd4f640e1f88ee355},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.18116. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The Sinoatrial node (SA), also called natural pacemaker, is responsible to initiate the heart electrical activity, usually represented by electrocardiograms (ECGs). Abnormalities at the SA node can produce disordered heart rhythms or, in other words, cardiac arrhythmia that are visualized in the ECGs. The development of control strategies to stabilize the cardiac rhythm at the natural pacemaker can provide efficient ways to deal with and avoid some heart pathology. This paper investigates the use of a robust controller based on sliding modes for cardiac rhythms at the SA node in order to induce normal rhythms from pathological responses. Embedded into this controller, a Gaussian process regressor is utilized to predict and compensate modeling uncertainties and disturbances. A mathematical model that presents close agreement with experimental measurements is employed to represent the heart functioning. The adopted model comprises a network of oscillators formed by sinoatrial node, atrioventricular node (AV) and His-Purkinje complex (HP). Three nonlinear oscillators are employed to represent each one of the nodes that are connected by delayed couplings. The boudedness and convergence properties are investigated with a Lyapunov-like stability analysis. In order to evaluate the ability of the control law to deal with interpatient variability, the heart model is assumed to be not available to the controller designer, being used only in the simulator to assess the control performance. The results show that, by applying the proposed control scheme, abnormal rhythms can be avoided, turning the ECG closer to the expected normal behavior and preventing critical cardiac responses.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-17 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.18116 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T17:54:20.009Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).