Metraipolis › archive › dc_223ef9fb63b7

CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation — arXiv:2611.01536

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.01536
License (as archived)
CC0-1.0
Archived
2026-11-03T18:53:27.529Z
SHA-256 of the archived text
e73d535c19f06d47b7b83952437cbe062529659df76d7033a9feaea169254c64
Stable URL of this page
https://metraipolis.com/documento/dc_223ef9fb63b7

How to cite

CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation — arXiv:2611.01536 — arXiv (en), https://arxiv.org/abs/2611.01536 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_223ef9fb63b7 (Metraipolis archive dc_223ef9fb63b7, sha256 e73d535c19f06d47b7b83952437cbe062529659df76d7033a9feaea169254c64)
BibTeX
@misc{dc223ef9fb63b7,
  title = {CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation — arXiv:2611.01536},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.01536},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_223ef9fb63b7; sha256 e73d535c19f06d47b7b83952437cbe062529659df76d7033a9feaea169254c64},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01536. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Registering intraoperative Ultrasound (US) bone-surface point clouds to preoperative Computed Tomography (CT) models can support radiation-free orthopedic navigation. Differences in imaging physics produce distinct surface sampling patterns, complicating cross-modal feature matching. Bone strongly reflects ultrasound and casts an acoustic shadow, so US captures only the probe-facing bone surface and leaves most CT points unmatched. This partial coverage makes correspondences ambiguous on near-symmetric bones. We propose CUFormer, a modality-aware registration framework. We introduce a Modality-Aware Transformer (MAT) that encodes input modality through identity embeddings and updates features through modality-specific adapters within a shared geometric matcher. We model imaging visibility and use predicted reference-side visibility to weight coarse and fine correspondences. CUFormer achieves the lowest mean registration errors among evaluated methods on two CT-US datasets, UltraBones100k and UltraBonesHip, and the CT-RGB-D dataset SpineDepth. On UltraBones100k, it reaches mean rotation error 4.53$^\circ$, translation error 3.19\,mm, and Root Mean Squared Error (RMSE) 2.54\,mm, reducing RMSE by 65.8\% relative to the best-performing baseline by this metric. These results demonstrate CUFormer's effectiveness in aligning partial bone surfaces with preoperative CT across anatomical sites.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2611.01536 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T18:16:52.931Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).