Metraipolis › archive › dc_22005929f90c
Bridging the Modality Gap in Long-Form Clinical Audio: A Comparative Study of Lightweight and Heavyweight End-to-End SOAP Generation — arXiv:2609.14467
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.14467
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T22:51:10.347Z
- SHA-256 of the archived text
d7f783befde97196c59a8e74bb461bd9f8f71806fe7ccc71a9b33635dc164f2b- Stable URL of this page
https://metraipolis.com/documento/dc_22005929f90c
How to cite
Bridging the Modality Gap in Long-Form Clinical Audio: A Comparative Study of Lightweight and Heavyweight End-to-End SOAP Generation — arXiv:2609.14467 — arXiv (en), https://arxiv.org/abs/2609.14467 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_22005929f90c (Metraipolis archive dc_22005929f90c, sha256 d7f783befde97196c59a8e74bb461bd9f8f71806fe7ccc71a9b33635dc164f2b)
BibTeX
@misc{dc22005929f90c,
title = {Bridging the Modality Gap in Long-Form Clinical Audio: A Comparative Study of Lightweight and Heavyweight End-to-End SOAP Generation — arXiv:2609.14467},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.14467},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_22005929f90c; sha256 d7f783befde97196c59a8e74bb461bd9f8f71806fe7ccc71a9b33635dc164f2b},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.14467. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Automating clinical documentation from long-form doctor-patient conversations remains challenging for modern audio-language models. While cascaded ASR systems perform well, end-to-end (E2E) models often struggle with information loss and hallucinations on extended audio. For the BeTraC 2026 challenge, the ASLP team presents a fully E2E multimodal system that generates structured SOAP notes directly from audio, bypassing intermediate transcripts. We constructed a 1.41-million-sample multi-task corpus and applied a multi-stage pipeline: domain pre-training, supervised fine-tuning, and reward optimization. Evaluating the architecture under both Lightweight (3B) and Heavyweight (30B) constraints reveals that each training stage progressively enhances performance. Furthermore, scaling to 30B parameters substantially boosts concept extraction and summarization quality. Ultimately, our E2E systems consistently outperform representative cascaded ASR+LLM baselines, proving the efficacy of direct multimodal optimization for clinical documentation. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.AI). Categorie arXiv: Sound (cs.SD) ; Artificial Intelligence (cs.AI); Audio and Speech Processing (eess.AS). Pagina del lavoro: https://arxiv.org/abs/2609.14467 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T22:29:03.678Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).