Metraipolis › archive › dc_21ff14f1b486

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation — arXiv:2609.37455

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.37455
License (as archived)
CC0-1.0
Archived
2026-10-07T19:15:40.185Z
SHA-256 of the archived text
33a78cab2e131c29f624022edaaee343bbe75c041b79ace6f27a44b782c7332f
Stable URL of this page
https://metraipolis.com/documento/dc_21ff14f1b486

How to cite

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation — arXiv:2609.37455 — arXiv (en), https://arxiv.org/abs/2609.37455 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_21ff14f1b486 (Metraipolis archive dc_21ff14f1b486, sha256 33a78cab2e131c29f624022edaaee343bbe75c041b79ace6f27a44b782c7332f)
BibTeX
@misc{dc21ff14f1b486,
  title = {Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation — arXiv:2609.37455},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.37455},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_21ff14f1b486; sha256 33a78cab2e131c29f624022edaaee343bbe75c041b79ace6f27a44b782c7332f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.37455. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-30 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.37455 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T18:40:59.509Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).