Metraipolis › archive › dc_21043ec1dcfe
Full Characterisation of the Polarisation Primary Beam of the GRAO 32-m Telescope — arXiv:2609.08700
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.08700
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T16:01:25.359Z
- SHA-256 of the archived text
a382cd2ca3cd2dd83e7fe3721dad3e805291d647d4deceb46686c40ba48df232- Stable URL of this page
https://metraipolis.com/documento/dc_21043ec1dcfe
How to cite
Full Characterisation of the Polarisation Primary Beam of the GRAO 32-m Telescope — arXiv:2609.08700 — arXiv (en), https://arxiv.org/abs/2609.08700 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_21043ec1dcfe (Metraipolis archive dc_21043ec1dcfe, sha256 a382cd2ca3cd2dd83e7fe3721dad3e805291d647d4deceb46686c40ba48df232)
BibTeX
@misc{dc21043ec1dcfe,
title = {Full Characterisation of the Polarisation Primary Beam of the GRAO 32-m Telescope — arXiv:2609.08700},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.08700},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_21043ec1dcfe; sha256 a382cd2ca3cd2dd83e7fe3721dad3e805291d647d4deceb46686c40ba48df232},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.08700. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Direction-dependent instrumental polarisation is a major systematic limitation in high-fidelity single-dish radio polarimetry, yet a unified characterisation of beam leakage and the conditioning of polarisation recovery is lacking for the Ghana Radio Astronomy Observatory (GRAO) 32-m telescope. We aim to establish a quantitative, direction-dependent polarimetric beam model at 5.0 and 6.7 GHz. High-resolution \texttt{GRASP} electromagnetic simulations of the nominal telescope configuration are used to derive the full complex Jones response and corresponding Mueller matrices, from which beam shape, beam squint, instrumental Stokes leakage, and intrinsic cross-polarisation ratio (IXR) are evaluated across the primary beam. The Stokes $I$ beams have half-power beam widths of $396.4$ and $295.3$ arcsec at 5.0 and 6.7 GHz, respectively, with main-beam efficiencies of $56.4$ and $55.6$ per cent. At 5.0 GHz, the circular-polarisation beam squint is $9.96$ arcsec ($2.5$ per cent of the HPBW), whereas no statistically significant squint is detected at 6.7 GHz. Leakage from Stokes $I$ into linear polarisation remains below $0.1$ per cent within the half-power beam but increases substantially towards the sidelobes. IXR reaches approximately $80$ dB on axis and decreases with angular offset. These results establish the intrinsic electromagnetic polarimetric response of the GRAO 32-m telescope and provide a quantitative baseline for direction-dependent calibration and subsequent observational validation.
Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-09 in physics.comp-ph).
Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM) ; Signal Processing (eess.SP); Mathematical Physics (math-ph); Computational Physics (physics.comp-ph); Instrumentation and Detectors (physics.ins-det).
Pagina del lavoro: https://arxiv.org/abs/2609.08700 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T15:44:54.350Z dalla pagina https://arxiv.org/catchup/physics.comp-ph/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).