Metraipolis › archive › dc_20e93992c198

SCALE: Synthetic Calibration via Agreement Labeling in Embedding Space — arXiv:2609.38705

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.38705
License (as archived)
CC0-1.0
Archived
2026-10-07T14:45:28.969Z
SHA-256 of the archived text
d30900515971502897629bb4ec434c7a9ec2634e2331bd9ca574955b800ce0b2
Stable URL of this page
https://metraipolis.com/documento/dc_20e93992c198

How to cite

SCALE: Synthetic Calibration via Agreement Labeling in Embedding Space — arXiv:2609.38705 — arXiv (en), https://arxiv.org/abs/2609.38705 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_20e93992c198 (Metraipolis archive dc_20e93992c198, sha256 d30900515971502897629bb4ec434c7a9ec2634e2331bd9ca574955b800ce0b2)
BibTeX
@misc{dc20e93992c198,
  title = {SCALE: Synthetic Calibration via Agreement Labeling in Embedding Space — arXiv:2609.38705},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.38705},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_20e93992c198; sha256 d30900515971502897629bb4ec434c7a9ec2634e2331bd9ca574955b800ce0b2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.38705. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Foundation models for computational pathology are usually evaluated using AUC and accuracy, while calibration is often left untested. This matters because a model can be accurate on average but still assign overly confident probabilities to cases that are difficult even for pathologists. We study calibration across eight pathology foundation models. Using pathologist agreement as a measure of diagnostic difficulty, we find that calibration error is consistently higher on low-agreement cases than on high-agreement cases. This pattern is not apparent from aggregate expected calibration error (ECE) alone. We then propose synthetic agreement calibration, a method for improving calibration without collecting multi-annotator labels. Given a trained linear probe, we select high-confidence embeddings as class anchors and interpolate between anchors from opposite classes. The interpolation weights encode a continuous notion of diagnostic ambiguity, which we use as a synthetic agreement signal to retrain the probe with agreement-aware label smoothing. On MHIST, which includes annotations from seven pathologists, synthetic agreement calibration recovers most of the calibration improvement obtained by label smoothing based on real pathologist agreement, while substantially reducing low-agreement ECE relative to the uncalibrated baseline. Discrimination metrics are preserved. On PatchCamelyon and BreakHis, public histopathology datasets without multi-annotator labels, the method improves calibration across the evaluated foundation models, whereas annotator-dependent approaches cannot be used without additional expert annotation.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-01 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.38705 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T14:19:00.600Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).