Metraipolis › archive › dc_20e1ace6bcc3
QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG — arXiv:2609.33351
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.33351
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T20:56:42.118Z
- SHA-256 of the archived text
919f03f547b7440aa72ae2aaf4655d9b0d3abfadcefb041d530a978f2b9ab846- Stable URL of this page
https://metraipolis.com/documento/dc_20e1ace6bcc3
How to cite
QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG — arXiv:2609.33351 — arXiv (en), https://arxiv.org/abs/2609.33351 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_20e1ace6bcc3 (Metraipolis archive dc_20e1ace6bcc3, sha256 919f03f547b7440aa72ae2aaf4655d9b0d3abfadcefb041d530a978f2b9ab846)
BibTeX
@misc{dc20e1ace6bcc3,
title = {QuPID: Quantum Parameter-Efficient Input-Dependent Retrieval Adaptation for Medical RAG — arXiv:2609.33351},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.33351},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_20e1ace6bcc3; sha256 919f03f547b7440aa72ae2aaf4655d9b0d3abfadcefb041d530a978f2b9ab846},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.33351. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Fidelity-based quantum retrieval ranks candidates by the fidelity between query and archive states. Applying a shared input-independent unitary after fixed state encoding leaves that fidelity unchanged, so training the circuit cannot alter the ranking. Quantum parameter-efficient input-dependent retrieval adaptation (QuPID) repairs this by making the circuit input-dependent through data re-uploading and by comparing measurement readouts, vectors of local Pauli expectations, rather than states. The result is a small readout for adapting frozen image features to a local archive with limited data: training simulates the circuit classically, and inference runs on a GPU with fixed learned parameters. We characterize the class as a structured factorization of input-modulated quadratic feature maps, bound the frequency support of its re-uploading channel, and give a parameter-count generalization bound that motivates its small budget. Under a shared frozen backbone and a label-free protocol, QuPID's 60 parameters give higher precision-at-5 (P@5) on ChestX-ray14 and MURA than frozen medical encoders, and than adapters and low-rank adaptation (LoRA) with up to 5.25 million trainable parameters. On ChestX-ray14, the P@5 gain over the frozen encoder is +0.116, the lead over retuned adapters is widest at 512 adaptation examples (+0.040), and the full-budget margin over an equally compact classical rotation-plane head is +0.023 with a 95% interval excluding zero. Medical imaging is the primary testbed; the pattern recurs on two non-medical benchmarks, in report generation, and under simulated gate noise and finite-shot readout. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI) ; Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2609.33351 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T20:29:01.226Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).