Metraipolis › archive › dc_20836c42bd4d

TriNetra: Thermal-Reliability-Guided RGB-Thermal Fusion and Tracking for Surveillance — arXiv:2611.09725

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.09725
License (as archived)
CC0-1.0
Archived
2026-11-09T22:45:27.723Z
SHA-256 of the archived text
ffb07bc44b529e8290257a66447c1a49cceb070531cecd12fbb55382be36f1e4
Stable URL of this page
https://metraipolis.com/documento/dc_20836c42bd4d

How to cite

TriNetra: Thermal-Reliability-Guided RGB-Thermal Fusion and Tracking for Surveillance — arXiv:2611.09725 — arXiv (en), https://arxiv.org/abs/2611.09725 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_20836c42bd4d (Metraipolis archive dc_20836c42bd4d, sha256 ffb07bc44b529e8290257a66447c1a49cceb070531cecd12fbb55382be36f1e4)
BibTeX
@misc{dc20836c42bd4d,
  title = {TriNetra: Thermal-Reliability-Guided RGB-Thermal Fusion and Tracking for Surveillance — arXiv:2611.09725},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.09725},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_20836c42bd4d; sha256 ffb07bc44b529e8290257a66447c1a49cceb070531cecd12fbb55382be36f1e4},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.09725. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Visible cameras fail at night and thermal sensors fail under saturation, blur or loss of contrast, yet most RGB-thermal (RGB-T) detectors mix the two streams with fixed weights and cannot tell when one modality has become unreliable. TriNetra is a reliability-aware surveillance framework built around this problem. The proposed solution computes a frame-level Thermal Reliability Coefficient (TRC) from five label-free image cues, uses it to gate the thermal features of a dual-branch YOLOv8m detector whose visible branch, neck and head are frozen and COCO-pretrained, and passes the same score to a ByteTrack-based tracker that feeds a rule-based behaviour analyser. On the M3FD benchmark (2,940/630/630 split) the detector reaches 87.6% precision, 79.4% recall, 70.0% mAP@50 and 47.8% mAP@50:95 on the test split, with 17.0 M of its 42.9 M parameters trained. TRC stays near 0.78 on clean frames (standard deviation 0.012), decreases with the severity of thermal saturation and blur, reaching 0.53 and 0.69 at full severity, and is insensitive to RGB-thermal misalignment. With identical weights, the adaptive gate matches a fixed gate on clean data (70.0% versus 69.8% mAP@50) but keeps 43.6% mAP@50 when the thermal stream is corrupted, against 38.4%, 29.2% and 25.0% for a fixed gate, full thermal admission and a closed gate; the 5.1-point gain over the fixed gate has a 95% bootstrap confidence interval of +3.6 to +6.5 points. In tracking, the TRC-gated association performs on par with ByteTrack on a synthetic benchmark with exact ground truth and on 14 M3FD clips, and is slightly less stable under thermal saturation, so its measured benefit is confined to the detector. The limitations of the current evaluation are reported together with the results.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2611.09725 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-09T22:37:47.233Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).