Metraipolis › archive › dc_207238e45057

S$^3$-Diff: Structural Semantic Synergy Diffusion Model for High Fidelity Super Resolution of Pathological Images — arXiv:2608.03540

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.03540
License (as archived)
CC0-1.0
Archived
2026-10-31T12:59:40.226Z
SHA-256 of the archived text
6d33727cadc06bbd3c612460349d41c1053f495a8ce8f13da43a63fc9a041673
Stable URL of this page
https://metraipolis.com/documento/dc_207238e45057

How to cite

S$^3$-Diff: Structural Semantic Synergy Diffusion Model for High Fidelity Super Resolution of Pathological Images — arXiv:2608.03540 — arXiv (en), https://arxiv.org/abs/2608.03540 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_207238e45057 (Metraipolis archive dc_207238e45057, sha256 6d33727cadc06bbd3c612460349d41c1053f495a8ce8f13da43a63fc9a041673)
BibTeX
@misc{dc207238e45057,
  title = {S$^3$-Diff: Structural Semantic Synergy Diffusion Model for High Fidelity Super Resolution of Pathological Images — arXiv:2608.03540},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.03540},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_207238e45057; sha256 6d33727cadc06bbd3c612460349d41c1053f495a8ce8f13da43a63fc9a041673},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.03540. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Digital pathology relies on high-resolution whole slide images for accurate diagnosis, yet limitations in imaging devices, storage, and transmission often make lower-resolution pathology images more common in clinical workflows. Current super-resolution techniques often tend to smooth diagnostically relevant morphology, leading to over-smoothed textures and semantic drift that compromise downstream clinical interpretation. To this end, we develop the Structural Semantic Synergy Diffusion Model (S3-Diff), a diffusion framework for high-fidelity super-resolution of pathological images. The core of S3-Diff is Specimen-aware Structural Anchoring (SSA), which combines prognosis-aware tissue support extracted by a fixed SAM with LR-HR gradient discrepancies to generate a specimen-specific structural anchor to preserve pathological morphology. Concurrently, we introduce Structure-guided Semantic Fidelity Tuning (SSFT) to adapt DINOv3 representations using SSA-derived structural supervision. SSFT combines the adapted semantic energy with LR-derived edge and grayscale cues. The resulting control guides denoising to suppress stochastic artifacts and maintain structural consistency. Extensive experimental results demonstrate that S3-Diff consistently outperforms state-of-the-art methods in both reconstruction quality and downstream survival analysis performance. The source code will be made public.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-05 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2608.03540 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T12:45:33.259Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).