Metraipolis › archive › dc_2052db095f15

Integrity Detection and Characterization of Malicious Injections in RAVEN II — arXiv:2609.33951

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.33951
License (as archived)
CC0-1.0
Archived
2026-10-08T00:17:15.531Z
SHA-256 of the archived text
1283ef0bb55fce239269388ec2e7353614864e76c1ddc83925d9926556e74617
Stable URL of this page
https://metraipolis.com/documento/dc_2052db095f15

How to cite

Integrity Detection and Characterization of Malicious Injections in RAVEN II — arXiv:2609.33951 — arXiv (en), https://arxiv.org/abs/2609.33951 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2052db095f15 (Metraipolis archive dc_2052db095f15, sha256 1283ef0bb55fce239269388ec2e7353614864e76c1ddc83925d9926556e74617)
BibTeX
@misc{dc2052db095f15,
  title = {Integrity Detection and Characterization of Malicious Injections in RAVEN II — arXiv:2609.33951},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.33951},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2052db095f15; sha256 1283ef0bb55fce239269388ec2e7353614864e76c1ddc83925d9926556e74617},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.33951. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The increasing adoption of robotic systems in surgery, together with the expanding range of procedures they can support and the growing level of autonomy they provide, has substantially increased the complexity of surgical robots. As these systems integrate more sensors, controllers, communication interfaces, and model-driven control components, their attack surface continues to expand. A compromise of the integrity of a surgical robot can therefore cause unintended robot behavior and potentially threaten patient safety. In this paper, we characterize the detection boundary of malicious injections on RAVEN II using a public dataset that pairs the platform's telemetry with external high-resolution encoder ground truth. We identify three injection points spanning the command and observation paths and evaluate three injection patterns with increasing temporal dispersion. To capture different detection behaviors, we perform detection at two timescales: the window scale and the session scale. Rather than reporting detection rates at an arbitrarily chosen threshold, we quantify, for each injection point and injection pattern, the smallest end-effector deviation that can be resolved while maintaining an alarm rate acceptable for surgical operation. Our results show that detectability is strongly influenced by how the injected deviation is distributed over time. An abrupt step can be detected at deviations well below the 1 mm clinical tolerance, whereas the same overall deviation spread across a window or a session can remain hidden from single-window statistics. The open source code can be found at this http URL .

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.33951 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:52:16.507Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).