Metraipolis › archive › dc_1ef744ff2157
Multivariable Geometric Laplace Transform and Fault Detection in Distributed-Converter Lines — arXiv:2609.02431
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.02431
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T06:27:56.025Z
- SHA-256 of the archived text
880a0959a270e1d04aa82ecae96de404cb940839a5ebca383d629d979f52fbbd- Stable URL of this page
https://metraipolis.com/documento/dc_1ef744ff2157
How to cite
Multivariable Geometric Laplace Transform and Fault Detection in Distributed-Converter Lines — arXiv:2609.02431 — arXiv (en), https://arxiv.org/abs/2609.02431 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1ef744ff2157 (Metraipolis archive dc_1ef744ff2157, sha256 880a0959a270e1d04aa82ecae96de404cb940839a5ebca383d629d979f52fbbd)
BibTeX
@misc{dc1ef744ff2157,
title = {Multivariable Geometric Laplace Transform and Fault Detection in Distributed-Converter Lines — arXiv:2609.02431},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.02431},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1ef744ff2157; sha256 880a0959a270e1d04aa82ecae96de404cb940839a5ebca383d629d979f52fbbd},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.02431. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Monitoring a DC line with many distributed power converters is a genuinely spatio-temporal problem: the information about a localized fault travels along the whole conductor and reaches a few measurement points mixed with the dynamics of the line itself. This paper develops a two-dimensional geometric Laplace transform (t,x) -> (s_t,s_x) over a commutative subalgebra of the geometric algebra Cl(4,0), isomorphic to Segre's bicomplex numbers, in which two bivectors B_t and B_x act as independent imaginary units for the temporal and the spatial phase. Because the two phases live in algebraically distinguishable planes, a fault at position x_f leaves a transformed residual that factorizes as F_f(s_t) e^{-s_x x_f}: its temporal nature stays in the first factor and its location can be read as a geometric argument of the second. On this representation we build a transmission-line model of the converter line and its space-time dispersion relation, a distributed control by admittance shaping, including an exact treatment of discrete converter sites (spatial sampling, aliasing, and a per-converter droop realization that is exact on the sub-Nyquist band), and a fault diagnosis chain that detects, localizes and classifies injection-loss, shunt, sensor and local-controller faults, extends to multiple simultaneous faults with automatic order selection, and distinguishes the outage of a plant from a cable defect. As an integral object the transform is known in bicomplex analysis, and with a single independent variable it reduces to the complex Laplace transform; the contribution lies in its geometric embedding and in its operational use for fault diagnosis in distributed-converter networks. All results are reproduced by an accompanying open implementation.
Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-03 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY) ; Signal Processing (eess.SP).