Metraipolis › archive › dc_1d93ae89a2b6
Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation… — arXiv:2610.34529
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.34529
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-27T08:01:29.416Z
- SHA-256 of the archived text
9b17b63df381d39ef17e9556bd58e72cbb1293f8cd614fbb7e6738756e4bcb90- Stable URL of this page
https://metraipolis.com/documento/dc_1d93ae89a2b6
How to cite
Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation… — arXiv:2610.34529 — arXiv (en), https://arxiv.org/abs/2610.34529 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1d93ae89a2b6 (Metraipolis archive dc_1d93ae89a2b6, sha256 9b17b63df381d39ef17e9556bd58e72cbb1293f8cd614fbb7e6738756e4bcb90)
BibTeX
@misc{dc1d93ae89a2b6,
title = {Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation… — arXiv:2610.34529},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.34529},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1d93ae89a2b6; sha256 9b17b63df381d39ef17e9556bd58e72cbb1293f8cd614fbb7e6738756e4bcb90},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.34529. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learning models achieve high single-dataset accuracy, they suffer from "shortcut learning" and domain shift in external validation. This study proposes a hierarchical computer-aided diagnostic (CAD) system mimicking emergency triage. Methods: We introduce a 3-channel Radiology-Focused Preprocessing pipeline that feeds radiological Hounsfield Unit (HU) windows into Convolutional Neural Network (CNN) and Vision Transformer (ViT) backbones via asymmetric formats (.mat and .png). The architecture utilizes a novel joint cross-attention fusion network optimized by an Integrated Orthogonal-Focal Loss. Results: Our system achieved a 95.48% F1-score on the internal stroke dataset. However, multi-center external validation (AISD, BHSD, PhysioNet) using a Mask Anchor filter revealed a drop to the 58-62% range, exposing the "internal validation illusion" caused by hardware noise. Critically, models exhibited high precision (77%) but low sensitivity (57%) for ischemic stroke, proving prone to hemorrhage overdiagnosis. Multi-seed variance analysis demonstrated that the DenseNet201+ViT backbone yielded the lowest deviation (0.59) and highest stability, making it the most reliable architecture for real-world clinical integration. Conclusions: To overcome diagnostic challenges, future research must focus on multimodal architectures that combine 3D volumetric extraction with clinical data. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.34529 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-27T07:55:30.912Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).