Metraipolis › archive › dc_1d6db10af083

Transient Triggering Grid-Forming Synchronization Control Under Voltage and Frequency Dips — arXiv:2609.39719

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.39719
License (as archived)
CC0-1.0
Archived
2026-10-07T16:05:20.314Z
SHA-256 of the archived text
49a800d1e20686fbab3c9d1ab225693e3fc7dd908f02e091eaef8f16a9f22ff2
Stable URL of this page
https://metraipolis.com/documento/dc_1d6db10af083

How to cite

Transient Triggering Grid-Forming Synchronization Control Under Voltage and Frequency Dips — arXiv:2609.39719 — arXiv (en), https://arxiv.org/abs/2609.39719 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1d6db10af083 (Metraipolis archive dc_1d6db10af083, sha256 49a800d1e20686fbab3c9d1ab225693e3fc7dd908f02e091eaef8f16a9f22ff2)
BibTeX
@misc{dc1d6db10af083,
  title = {Transient Triggering Grid-Forming Synchronization Control Under Voltage and Frequency Dips — arXiv:2609.39719},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.39719},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1d6db10af083; sha256 49a800d1e20686fbab3c9d1ab225693e3fc7dd908f02e091eaef8f16a9f22ff2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.39719. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Grid-forming (GFM) inverters are gaining attention as a promising alternative for conventional synchronous generators in the modern power systems. Unlike conventional synchronous generators, GFM inverters have limited overcurrent capability that makes them vulnerable during large disturbances. During disturbances i.e., voltage and frequency dips, GFM inverters are pushed into current-limited operation to protect the semiconductor switches. This causes the internal angle of the GFM inverters to accelerate and lose synchronism with the rest of the grid. To address this limitation, this article proposes a transient triggering grid-forming (TTGFM) synchronization control to enhance the synchronization stability performance under voltage and frequency dips. This method uses two feedback signals; terminal voltage and the difference between unsaturated and saturated power to adjust the internal angle which is generated by power synchronization loop (PSL) of the GFM inverters. These two signals manipulates the internal reference angle generation that act as a virtual braking mechanism. This mechanism limits the angle acceleration during voltage and frequency dips without requiring an extra supervisory signal or parameters to tune. The proposed method is benchmarked against two state-of-the-art synchronization enhancement schemes and validated through high-fidelity electromagnetic transient (EMT) simulations with a grid dynamic equivalent (GDE) model in MATLAB/Simulink\textsuperscript{\textregistered}. An analytical framework is developed to derive the synchronization instability mechanism and the critical limits of the stability margins. Generalization of the GDE model further shows that the TTGFM control is not restricted to a single configuration but is applicable to any standard benchmark system.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-10-01 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.39719 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T15:38:32.030Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).