Metraipolis › archive › dc_1d02e2e68c6a
CHILD: Human-in-the-Loop OOD Detection for Safe Clinical Deployment — arXiv:2609.07188
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.07188
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T15:11:43.882Z
- SHA-256 of the archived text
ccbf82aa6052f3b3c47a883b1e6baa5567cb58fc44053c75313122ea249b8afb- Stable URL of this page
https://metraipolis.com/documento/dc_1d02e2e68c6a
How to cite
CHILD: Human-in-the-Loop OOD Detection for Safe Clinical Deployment — arXiv:2609.07188 — arXiv (en), https://arxiv.org/abs/2609.07188 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1d02e2e68c6a (Metraipolis archive dc_1d02e2e68c6a, sha256 ccbf82aa6052f3b3c47a883b1e6baa5567cb58fc44053c75313122ea249b8afb)
BibTeX
@misc{dc1d02e2e68c6a,
title = {CHILD: Human-in-the-Loop OOD Detection for Safe Clinical Deployment — arXiv:2609.07188},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.07188},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1d02e2e68c6a; sha256 ccbf82aa6052f3b3c47a883b1e6baa5567cb58fc44053c75313122ea249b8afb},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.07188. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Out-of-distribution (OOD) detection is critical for safe deployment of medical AI systems. Recently, test-time adaptation (TTA) has emerged as a new paradigm for OOD detection, automatically adjusting detector behavior during deployment. However, such automatic adaptation mechanisms may raise safety concerns in safety-critical clinical environments. While physician oversight can mitigate these risks, it is resource-intensive and must be judiciously allocated. To reconcile safety with efficiency, we propose CHILD, a training-free framework designed to enhance streaming OOD detection via sparse human feedback. Operating under strict budget constraints, CHILD employs an adaptive risk-aware sample selection mechanism to pinpoint only the most decision-uncertain samples for review. Crucially, it maximizes the utility of this sparse feedback through a retrieval-based score calibration module, which refines model predictions using a compact feature cache without any parameter updates. Extensive experiments on four medical benchmarks demonstrate that CHILD turns limited supervision into significant reliability gains: with a sparse feedback budget of only 5%, it reduces the average FPR95 from 72.63% to 60.26% and improves AUROC from 75.53% to 81.85%, consistently outperforming state-of-the-art baselines. Our code is publicly available at this https URL . Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-09 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.07188 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T14:49:57.201Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).