Metraipolis › archive › dc_1ccb4c8da1e8
Multi-Channel Feature Fusion and Monte Carlo Dropout for Uncertainty-Aware Diabetic Retinopathy Grading — arXiv:2608.15234
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.15234
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T02:16:11.260Z
- SHA-256 of the archived text
1df9adc5771966f05d427c7e8e4f025b21e691053c7f558e91f579cb724c0443- Stable URL of this page
https://metraipolis.com/documento/dc_1ccb4c8da1e8
How to cite
Multi-Channel Feature Fusion and Monte Carlo Dropout for Uncertainty-Aware Diabetic Retinopathy Grading — arXiv:2608.15234 — arXiv (en), https://arxiv.org/abs/2608.15234 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1ccb4c8da1e8 (Metraipolis archive dc_1ccb4c8da1e8, sha256 1df9adc5771966f05d427c7e8e4f025b21e691053c7f558e91f579cb724c0443)
BibTeX
@misc{dc1ccb4c8da1e8,
title = {Multi-Channel Feature Fusion and Monte Carlo Dropout for Uncertainty-Aware Diabetic Retinopathy Grading — arXiv:2608.15234},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.15234},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1ccb4c8da1e8; sha256 1df9adc5771966f05d427c7e8e4f025b21e691053c7f558e91f579cb724c0443},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.15234. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Automated five-stage diabetic retinopathy (DR) grading requires more than high accuracy alone. Medical-grade deployment calls for lesion-aware preprocessing, ordinal predictions, calibrated uncertainty, and explainability to support reliable diagnostic systems. We present a unified pipeline that addresses these requirements using a Ben-Graham-green-channel CLAHE feature representation, an EfficientNetV2-L ordinal regressor, and Monte Carlo dropout for uncertainty-driven referral. Grad-CAM provides visual explanations aligned with clinically relevant lesions. The proposed method achieves a QWK of 91.31% on the APTOS-2019 official test split, placing it within the near-perfect agreement band (>80%). At a 20% referral rate, 293 of 366 images are automatically graded with a QWK of 90.40%. More complex cases are referred for specialist assessment, demonstrating a practical trade-off among grading quality, automation, and patient safety in robust, reliable, and deployment-ready medical diagnostic systems. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-18 in eess.SP). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2608.15234 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T01:25:14.342Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-08-18?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).