Metraipolis › archive › dc_1bee86c91307

Langmuir Probe Measurements in the Gaseous Electronics Conference RF Reference Cell — Europe PMC PMID:29151751

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/29151751
DOI
10.6028/jres.100.031
License (as archived)
CC0-1.0
Archived
2026-10-08T10:23:17.457Z
SHA-256 of the archived text
7e5face31f26375f4b5908a862fcb17bda9c88d0bd8cfc90d4e4d0a178b0917d
Stable URL of this page
https://metraipolis.com/documento/dc_1bee86c91307

How to cite

Langmuir Probe Measurements in the Gaseous Electronics Conference RF Reference Cell — Europe PMC PMID:29151751 — Europe PMC (en), https://europepmc.org/article/MED/29151751 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1bee86c91307 (Metraipolis archive dc_1bee86c91307, sha256 7e5face31f26375f4b5908a862fcb17bda9c88d0bd8cfc90d4e4d0a178b0917d)
BibTeX
@misc{dc1bee86c91307,
  title = {Langmuir Probe Measurements in the Gaseous Electronics Conference RF Reference Cell — Europe PMC PMID:29151751},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/29151751},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1bee86c91307; sha256 7e5face31f26375f4b5908a862fcb17bda9c88d0bd8cfc90d4e4d0a178b0917d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/29151751. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The use of a Langmuir probe system in two GEC cells is reviewed. The major problems associated with probe diagnostics in a GEC cell are outlined and discussed. While the data base is still insufficient to give definitive values for many parameters, a number of standard measurements are put forward. The plasma density in argon is 9×10 9 cm -3 (±20 %) at an applied rf voltage of 250 V (500 V peak to peak) and a gas pressure of 13.3 Pa (100 mTorr). The electron density scales linearly with applied voltage. The plasma to ground sheath resistance is shown to be very important with a value of 810 Ω in argon at a pressure of 13.3 Pa (100 mTorr) and discharge current of 0.1 A. The value of plasma to ground resistance scales inversely with discharge current and sublinear with pressure. Two standard features in the electron energy distribution function (EEDF) have been proposed as a test of the ability of a probe system to resolve features, first, the transition from a low temperature (<1 eV) bi-Maxwellian distribution to a Druyveysten distribution (3 eV) at 13.3 Pa (100 mTorr) in argon, and the "hole" in the EEDF at 2 eV to 4 eV in nitrogen plasmas.

Tema degli esploratori: fisica e astronomia (ricerca Europe PMC «plasma physics», solo open access).
Pubblicazione: Journal of research of the National Institute of Standards and Technology, 1995 (prima pubblicazione 1995-07-01).
Identificativi: PMID 29151751 · PMCID PMC4887235 · DOI 10.6028/jres.100.031.
Parole chiave degli autori: Gec Cell; Langmuir Probe; Plasma Diagnostic.