Metraipolis › archive › dc_1b5b3afa72c2

Generalized H matrix stability for power systems — arXiv:2611.09796

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.09796
License (as archived)
CC0-1.0
Archived
2026-11-09T23:03:36.822Z
SHA-256 of the archived text
66f4a355bb006e42fbe831e01b7427890755a96a5b1d306a84fb04ba2952a095
Stable URL of this page
https://metraipolis.com/documento/dc_1b5b3afa72c2

How to cite

Generalized H matrix stability for power systems — arXiv:2611.09796 — arXiv (en), https://arxiv.org/abs/2611.09796 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1b5b3afa72c2 (Metraipolis archive dc_1b5b3afa72c2, sha256 66f4a355bb006e42fbe831e01b7427890755a96a5b1d306a84fb04ba2952a095)
BibTeX
@misc{dc1b5b3afa72c2,
  title = {Generalized H matrix stability for power systems — arXiv:2611.09796},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.09796},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1b5b3afa72c2; sha256 66f4a355bb006e42fbe831e01b7427890755a96a5b1d306a84fb04ba2952a095},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.09796. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The small-signal stability of a power system model with arbitrary loads is investigated, with a focus on locally constant power loads in lossless networks. A central element of the proposed analysis is the matrix H, which represents the partial derivatives of generator powers with respect to their relative angles. The local stability of any equilibrium point is determined by the properties of H if the loads consume locally constant power. Specifically, an equilibrium point is asymptotically stable if H is positive definite and unstable if H is full-rank and not positive definite, while several quantitative relationships between the eigenvalues of H and the system Jacobian matrix are also established. The main contribution is that loads are allowed to be arbitrarily located within the transmission network, thereby generalizing the existing H matrix stability criterion which is valid only if loads are located at the same buses as the generators. The advantage of the proposed criterion is demonstrated through case studies involving systems with up to 2869 buses. Accurate stability assessments are maintained, where alternative methods, such as the NRPS model, are found to be overly conservative. Additionally, a computational acceleration by a factor of 340 relative to Jacobian-based methods is achieved.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2611.09796 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-09T22:58:52.108Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).