Metraipolis › archive › dc_1adbb3b487f3

Assessing Covariate-Informed Grid Load Forecasting with a Time-Series Foundation Model — arXiv:2609.06656

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.06656
License (as archived)
CC0-1.0
Archived
2026-10-16T13:57:16.604Z
SHA-256 of the archived text
168f0fbf1c1ed27e6323cc5d698627e0b8ef6c4a7cd47c07f0880f3ea1bfa05b
Stable URL of this page
https://metraipolis.com/documento/dc_1adbb3b487f3

How to cite

Assessing Covariate-Informed Grid Load Forecasting with a Time-Series Foundation Model — arXiv:2609.06656 — arXiv (en), https://arxiv.org/abs/2609.06656 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1adbb3b487f3 (Metraipolis archive dc_1adbb3b487f3, sha256 168f0fbf1c1ed27e6323cc5d698627e0b8ef6c4a7cd47c07f0880f3ea1bfa05b)
BibTeX
@misc{dc1adbb3b487f3,
  title = {Assessing Covariate-Informed Grid Load Forecasting with a Time-Series Foundation Model — arXiv:2609.06656},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.06656},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1adbb3b487f3; sha256 168f0fbf1c1ed27e6323cc5d698627e0b8ef6c4a7cd47c07f0880f3ea1bfa05b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.06656. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Modern power systems are growing increasingly complex as they integrate diverse generation sources to meet rising demand, making accurate load forecasting challenging. Recent advances in time-series foundation models (TSFMs) resulted in promising performance in zero-shot univariate load forecasting tasks. However, real-world load forecasting often involves multiple target variables and requires the integration of exogenous variables, raising important questions about the utility of TSFMs in realistic settings. In this study, we position Chronos-2, a recently developed model by Amazon, as a representative multi-channel TSFM that supports univariate, multivariate, and covariate-informed forecasting, and conduct a systematic investigation of how such models can be used for real-world load forecasting. While prior work has evaluated Chronos-2 on a limited number of energy-related tasks in a zero-shot setting, its performance relative to established task-specific deep learning models and its behavior when adapted using task-specific historical data remains insufficiently understood. In this work, we evaluate Chronos-2 on two real-world utility datasets, ISO New England and ENTSO-E, and benchmark it against widely used task-specific deep learning models. Our results show that Chronos-2 benefits substantially from task-specific fine-tuning and achieves strong short-horizon forecasting performance, but its zero-shot accuracy lags behind task-specific models and its forecasting error grows more rapidly with increasing forecast steps. Overall, this study provides a detailed characterization of the strengths and limitations of TSFMs such as Chronos-2 in grid load forecasting and offers practical insights into how a pretrained TSFM can be effectively adapted for operational load forecasting applications.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-09 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI); Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.06656 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T13:39:42.902Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).