Metraipolis › archive › dc_1aca35c100e6
Frequency Measurement Practices for Inertia Assessment in Inverter Based Resources Dominated Power Systems — arXiv:2609.34531
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.34531
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T01:34:14.489Z
- SHA-256 of the archived text
5802b316826ef86c13f2096a616b2aea5ae9424297385042f814657e16ec4004- Stable URL of this page
https://metraipolis.com/documento/dc_1aca35c100e6
How to cite
Frequency Measurement Practices for Inertia Assessment in Inverter Based Resources Dominated Power Systems — arXiv:2609.34531 — arXiv (en), https://arxiv.org/abs/2609.34531 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1aca35c100e6 (Metraipolis archive dc_1aca35c100e6, sha256 5802b316826ef86c13f2096a616b2aea5ae9424297385042f814657e16ec4004)
BibTeX
@misc{dc1aca35c100e6,
title = {Frequency Measurement Practices for Inertia Assessment in Inverter Based Resources Dominated Power Systems — arXiv:2609.34531},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.34531},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1aca35c100e6; sha256 5802b316826ef86c13f2096a616b2aea5ae9424297385042f814657e16ec4004},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.34531. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Transmission system operators and protective relays compute the rate of change of frequency (RoCoF) from frequency averaged over tens to hundreds of milliseconds, as standards and grid codes specify. Any response delivered inside that window lowers the measured RoCoF, so the inferred inertia depends on the window and the responses in service. This paper defines the windowed inertia estimate and derives an exact identity the system inertia divided by one minus the fraction of the disturbance energy delivered inside the window and a closed-form prediction that applies the same estimator to the trajectory of a linear response model. Eleven IEEE 9-bus RMS runs synchronous, grid-following and grid-forming configurations, disturbance sizes and parameter sweeps are reproduced by that model, and the identity closes on the measured response powers. Fast frequency response inflates the estimate most: at 500 ms a grid-following system with 20 % less synchronous inertia reports the same value as the all-synchronous system, the grid-forming system a higher one. On a reduced Greek transmission system the 500ms estimate exceeds the inertia by 17-26%, and a scenario with 10% less synchronous inertia reports more than the all-synchronous scenario's inertia. Operators can thus compute what their measurement reports. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-29 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.34531 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T01:10:47.838Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).