Metraipolis › archive › dc_18f5e3caa984
Detection of SARS-CoV-2 RNA by multiplex RT-qPCR — Europe PMC PMID:33027248
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/33027248
- DOI
- 10.1371/journal.pbio.3000867
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-07T08:43:30.394Z
- SHA-256 of the archived text
51081cffdb5191e795e843fcbbac3055f8ff703239d8f5f899529e89a5fc43ae- Stable URL of this page
https://metraipolis.com/documento/dc_18f5e3caa984
How to cite
Detection of SARS-CoV-2 RNA by multiplex RT-qPCR — Europe PMC PMID:33027248 — Europe PMC (en), https://europepmc.org/article/MED/33027248 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_18f5e3caa984 (Metraipolis archive dc_18f5e3caa984, sha256 51081cffdb5191e795e843fcbbac3055f8ff703239d8f5f899529e89a5fc43ae)
BibTeX
@misc{dc18f5e3caa984,
title = {Detection of SARS-CoV-2 RNA by multiplex RT-qPCR — Europe PMC PMID:33027248},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/33027248},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_18f5e3caa984; sha256 51081cffdb5191e795e843fcbbac3055f8ff703239d8f5f899529e89a5fc43ae},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/33027248. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The current quantitative reverse transcription PCR (RT-qPCR) assay recommended for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing in the United States requires analysis of 3 genomic targets per sample: 2 viral and 1 host. To simplify testing and reduce the volume of required reagents, we devised a multiplex RT-qPCR assay to detect SARS-CoV-2 in a single reaction. We used existing N1, N2, and RP primer and probe sets by the Centers for Disease Control and Prevention, but substituted fluorophores to allow multiplexing of the assay. The cycle threshold (Ct) values of our multiplex RT-qPCR were comparable to those obtained by the single assay adapted for research purposes. Low copy numbers (≥500 copies/reaction) of SARS-CoV-2 RNA were consistently detected by the multiplex RT-qPCR. Our novel multiplex RT-qPCR improves upon current single diagnostics by saving reagents, costs, time, and labor. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PLoS biology, 2020 (prima pubblicazione 2020-10-07). Identificativi: PMID 33027248 · PMCID PMC7571696 · DOI 10.1371/journal.pbio.3000867. Pagina: https://europepmc.org/article/MED/33027248 — https://doi.org/10.1371/journal.pbio.3000867. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-07T08:39:10.813Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.