Metraipolis › archive › dc_18f323b657cb
A Closed-Loop Model of an Anion Exchange Membrane Electrolyser Based on Operational Data — arXiv:2609.18638
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.18638
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T18:22:41.592Z
- SHA-256 of the archived text
40af852b03f3f4856b5186332dfc1f895e4a49a27db34e234ce9d42171c5c6e2- Stable URL of this page
https://metraipolis.com/documento/dc_18f323b657cb
How to cite
A Closed-Loop Model of an Anion Exchange Membrane Electrolyser Based on Operational Data — arXiv:2609.18638 — arXiv (en), https://arxiv.org/abs/2609.18638 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_18f323b657cb (Metraipolis archive dc_18f323b657cb, sha256 40af852b03f3f4856b5186332dfc1f895e4a49a27db34e234ce9d42171c5c6e2)
BibTeX
@misc{dc18f323b657cb,
title = {A Closed-Loop Model of an Anion Exchange Membrane Electrolyser Based on Operational Data — arXiv:2609.18638},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.18638},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_18f323b657cb; sha256 40af852b03f3f4856b5186332dfc1f895e4a49a27db34e234ce9d42171c5c6e2},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.18638. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The main contribution of this work is to identify model parameters for an Anion Exchange Membrane (AEM) system directly from measured operational data, enabling their use in power system studies. Due to the relatively low technology readiness level (TRL) of AEM electrolysers, only limited literature reports operational parameters supported by openly available experimental data. By capturing the realistic dynamic behaviour and power consumption of the AEM electrolyser, this model allows for more accurate evaluation of system topologies and control strategies for green hydrogen production. This paper presents a model of an AEM electrolyser based on experimental data from Enapter modules installed in the Power-to-X (PtX) Laboratory at the Technical University of Denmark [1]. The model comprises a polarisation curve and a model of current dynamics during operation. It is validated against operational data and can be applied in grid-balancing studies as well as in assessments of how electrolyser dynamics influence the power system. The results suggest that the AEM technology is suitable for services such as smoothing wind farm power output and provide system services to support frequency balancing. The findings highlight the importance of considering the constraints of the process when designing for flexible load operation, and consideration of the interaction between the power control and process control systems. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-17 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.18638 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T17:54:20.019Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).