Metraipolis › archive › dc_16acb5738bb3
When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation — arXiv:2609.31733
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.31733
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T23:50:32.688Z
- SHA-256 of the archived text
39804403891b70ec8a5539e03ba6ba44099c4401cceffe63454bf21e6f3d4233- Stable URL of this page
https://metraipolis.com/documento/dc_16acb5738bb3
How to cite
When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation — arXiv:2609.31733 — arXiv (en), https://arxiv.org/abs/2609.31733 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_16acb5738bb3 (Metraipolis archive dc_16acb5738bb3, sha256 39804403891b70ec8a5539e03ba6ba44099c4401cceffe63454bf21e6f3d4233)
BibTeX
@misc{dc16acb5738bb3,
title = {When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation — arXiv:2609.31733},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.31733},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_16acb5738bb3; sha256 39804403891b70ec8a5539e03ba6ba44099c4401cceffe63454bf21e6f3d4233},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31733. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Retrieval-augmented generation is an attractive way to improve chest X-ray reporting, because reports from similar prior studies supply clinical context a general vision-language model lacks. We show the same mechanism is a reliable source of clinical error. Over 100 MIMIC-CXR studies with a frozen LLaVA-1.5 generator and BioMedCLIP retrieval, CheXbert clinical F1 doubles under relevant retrieval (0.201 to 0.402) and collapses to 0.043 under clinically mismatched retrieval, a fifth of the image-only score; the retrieval-induced hallucination rate, counting only unsupported findings traceable to retrieved evidence, rises from 0.00 to 0.76 and 0.98. To show this is not an artefact of evidence-set coverage, we introduce a coincidental-overlap control that scores image-only generations against evidence they never saw, placing the chance base rate at 0.18, four to five times below the observed rates. The generator does not merely acquire findings, it transcribes text: 95% of reports produced under relevant retrieval contain an eight-word span occurring verbatim in the retrieved evidence but absent from the reference, against 0% without retrieval. We then explain the mechanism: a normal chest X-ray retrieves at least one abnormal precedent in 24 of 28 cases, because medical image-embedding similarity is dominated by anatomy and acquisition rather than by the presence of disease. This has a direct design consequence. Retrieval similarity does not predict harm (RIH rates 0.80/0.80/0.60/0.84 across similarity quartiles), so relevance gates conditioned on embedding similarity cannot work; gating on predicted pathology agreement removes 61% of unsupported evidence at no cost to useful coverage. We argue that retrieval-augmented clinical systems must be evaluated under retrieval failure, not only under retrieval success. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.31733 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T23:29:26.901Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).