Metraipolis › archive › dc_1585799cfbb0
Quantum-Inspired Hamiltonian Descent for Radiation Therapy Treatment Planning — arXiv:2611.00989
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00989
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T18:45:16.756Z
- SHA-256 of the archived text
69866d12d250ffff6d1d51f7d0f6323b08053354fdc9216f992cd8afb94c511e- Stable URL of this page
https://metraipolis.com/documento/dc_1585799cfbb0
How to cite
Quantum-Inspired Hamiltonian Descent for Radiation Therapy Treatment Planning — arXiv:2611.00989 — arXiv (en), https://arxiv.org/abs/2611.00989 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1585799cfbb0 (Metraipolis archive dc_1585799cfbb0, sha256 69866d12d250ffff6d1d51f7d0f6323b08053354fdc9216f992cd8afb94c511e)
BibTeX
@misc{dc1585799cfbb0,
title = {Quantum-Inspired Hamiltonian Descent for Radiation Therapy Treatment Planning — arXiv:2611.00989},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00989},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1585799cfbb0; sha256 69866d12d250ffff6d1d51f7d0f6323b08053354fdc9216f992cd8afb94c511e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00989. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Direct incorporation of dose-volume constraints into inverse radiotherapy planning leads to large mixed-integer optimization problems that accurately represent clinical requirements but are computationally challenging. We develop and evaluate a quantum-inspired approach for automated dose-volume-constrained intensity-modulated radiation therapy (IMRT) and intensity-modulated proton therapy (IMPT) planning. Clinical requirements are formulated as mixed-integer optimization problems, with binary variables representing dose-volume constraint violations. Patient-specific dose-influence matrices are generated at the photon control-point and proton spot levels, and intensities are optimized using Quantum-Inspired Hamiltonian Descent (QIHD). We evaluate QIHD on eight clinical cases: four IMRT (two prostate, one head-and-neck, and one liver) and four IMPT (two lung, one prostate, and one liver). The IMRT formulations contain 27,621 to 112,565 variables and are solved in 5 to 32 minutes, while the IMPT formulations contain 69,861 to 221,342 variables and are solved in 11 to 35 minutes on an NVIDIA RTX 4060 GPU. QIHD produces dose distributions satisfying clinical protocols without manual intervention. In comparison, a CPU implementation of Gurobi fails to solve most tested mixed-integer formulations within several hours. These results demonstrate the computational feasibility of GPU-accelerated QIHD for automated photon and proton treatment planning. Prospective clinical validation and implementation of decomposed subproblems on quantum hardware remain future directions. Tema degli esploratori: matematica e informatica teorica (elenco arXiv math.OC, nuovi lavori del giorno). Categorie arXiv: Optimization and Control (math.OC). Pagina del lavoro: https://arxiv.org/abs/2611.00989 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T18:14:37.751Z dalla pagina https://arxiv.org/list/math.OC/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).