Metraipolis › archive › dc_14df044f8183

Cross-modal topology decodes battery faults from sparse voltage snapshots — arXiv:2608.10825

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.10825
License (as archived)
CC0-1.0
Archived
2026-10-19T06:48:19.957Z
SHA-256 of the archived text
59042c13a775e22fb15b4aa788614bfcdcc515b2a61f481e2a67205fbefa9b25
Stable URL of this page
https://metraipolis.com/documento/dc_14df044f8183

How to cite

Cross-modal topology decodes battery faults from sparse voltage snapshots — arXiv:2608.10825 — arXiv (en), https://arxiv.org/abs/2608.10825 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_14df044f8183 (Metraipolis archive dc_14df044f8183, sha256 59042c13a775e22fb15b4aa788614bfcdcc515b2a61f481e2a67205fbefa9b25)
BibTeX
@misc{dc14df044f8183,
  title = {Cross-modal topology decodes battery faults from sparse voltage snapshots — arXiv:2608.10825},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.10825},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_14df044f8183; sha256 59042c13a775e22fb15b4aa788614bfcdcc515b2a61f481e2a67205fbefa9b25},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.10825. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Battery safety remains the primary bottleneck for mass electric vehicle (EV) adoption, yet field monitoring is hamstrung by a fundamental asymmetry: complex electrochemical faults must be diagnosed via sparse, low-frequency voltage measurements. Existing methods struggle to resolve the signal ambiguity between overlapping fault modes without hardware upgrades. Here, we demonstrate that these distinct fault fingerprints are not lost, but topologically folded within voltage snapshots. We introduce DeFault, a cross-modal diagnostic framework that mathematically unfolds one-dimensional voltage sequences into multi-dimensional phase-space topologies. DeFault employs a bidirectional cross-attention mechanism that acts as an autonomous, physics-aligned filter, explicitly decoding compounded fault modes that remain fundamentally invisible to sequence-based methods. Validated on a field dataset of 16.4 million data records from 99 in-service EVs, our method achieves an average accuracy of 0.96 and an F1 score of 0.84 for four fault types using only 500-second snapshots (spanning <100 mV). This work proves that high-fidelity, interpretable electrochemical diagnosis is achievable on legacy fleets without new sensors, providing a scalable solution for the battery safety crisis.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-12 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2608.10825 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T06:41:52.240Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-08-12?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).