Metraipolis › archive › dc_1477f134ee4a

Controller- and Communication-Aware Flexibility Margins for Electric Distribution Networks — arXiv:2610.20484

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.20484
License (as archived)
CC0-1.0
Archived
2026-10-15T15:03:04.690Z
SHA-256 of the archived text
bcd55f67609999b6ab582b108034535cc4d062668f59397802f2e6cd5dcf86fe
Stable URL of this page
https://metraipolis.com/documento/dc_1477f134ee4a

How to cite

Controller- and Communication-Aware Flexibility Margins for Electric Distribution Networks — arXiv:2610.20484 — arXiv (en), https://arxiv.org/abs/2610.20484 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_1477f134ee4a (Metraipolis archive dc_1477f134ee4a, sha256 bcd55f67609999b6ab582b108034535cc4d062668f59397802f2e6cd5dcf86fe)
BibTeX
@misc{dc1477f134ee4a,
  title = {Controller- and Communication-Aware Flexibility Margins for Electric Distribution Networks — arXiv:2610.20484},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.20484},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_1477f134ee4a; sha256 bcd55f67609999b6ab582b108034535cc4d062668f59397802f2e6cd5dcf86fe},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.20484. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This paper develops a framework for quantifying operational flexibility in radial electric distribution systems under coupled active- and reactive-load uncertainty. Flexibility is defined as the largest scaling of a prescribed uncertainty set that can be accommodated while satisfying network and actuator limits under a given control architecture. We consider a one-sided Euclidean set for robust demand-growth capability, with a direct extension to bidirectional variations. Under LinDistFlow, controllable distributed resources and feeder-head exchange with the upstream grid jointly balance active-power disturbances, while local Volt/VAR feedback regulates reactive power. The resulting affine closed-loop disturbance response admits exact second-order-cone robust counterparts. For fixed Volt/VAR gains, a convex reformulation jointly optimizes the flexibility margin and active-power participation factors, including feeder-head participation. A sparse load-to-generator feedforward map further captures communication constraints. Numerical studies on the Iowa-240 feeder demonstrate how the amount of control authority and communication structure shape the achievable flexibility margin.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2610.20484 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T14:07:08.603Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).