Metraipolis › archive › dc_13f248e87667
Equivalent Modeling of Load-Side Systems With Distributed Renewable Generation Considering Fault Responses and Nodal Voltage Coherence — arXiv:2609.24262
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.24262
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T00:55:29.078Z
- SHA-256 of the archived text
757a084a29f5227ccd87831f0a60474f1967432479bae398746de2efe1c47e59- Stable URL of this page
https://metraipolis.com/documento/dc_13f248e87667
How to cite
Equivalent Modeling of Load-Side Systems With Distributed Renewable Generation Considering Fault Responses and Nodal Voltage Coherence — arXiv:2609.24262 — arXiv (en), https://arxiv.org/abs/2609.24262 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_13f248e87667 (Metraipolis archive dc_13f248e87667, sha256 757a084a29f5227ccd87831f0a60474f1967432479bae398746de2efe1c47e59)
BibTeX
@misc{dc13f248e87667,
title = {Equivalent Modeling of Load-Side Systems With Distributed Renewable Generation Considering Fault Responses and Nodal Voltage Coherence — arXiv:2609.24262},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.24262},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_13f248e87667; sha256 757a084a29f5227ccd87831f0a60474f1967432479bae398746de2efe1c47e59},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.24262. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Operating conditions and fault severity change both the initial states and control modes of active distribution networks. Direct capacity aggregation can therefore lose the power responses required for transmission-system dynamic analysis. This paper develops a procedure for generating low-order physical electromagnetic transient equivalents from a small set of representative operating conditions. Device power, ride-through states, load mechanical states, and local sequence voltages are combined with electrical distance to form response families. Response reconstruction and terminal simulation errors determine the retained architecture, after which bounded sensitivity calculations determine effective dynamic coefficients. The architecture and coefficients are then fixed. For a new operating condition, capacity and power balances, voltage-dependent load relations, and an initialization correction generate the model parameters from static inputs and power-flow results. A representative severe fault establishes a template for each fault type, which is reused across fault depths. Aggregation and switching-time bounds explain the roles of voltage coherence and state separation. Comparisons with direct aggregation show improved terminal responses across operating conditions and several fault types, with the largest gains under severe unbalanced faults. The method provides a reusable physical equivalent for operating-condition studies and fault-depth screening. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-22 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.24262 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T23:57:37.633Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).