Metraipolis › archive › dc_13c48b70cddc
ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration — arXiv:2610.11003
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.11003
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T06:33:11.078Z
- SHA-256 of the archived text
b7bc3dc90c7a64187ccb0a5538299a5dceb593e6fb01182c13e0ba50367394aa- Stable URL of this page
https://metraipolis.com/documento/dc_13c48b70cddc
How to cite
ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration — arXiv:2610.11003 — arXiv (en), https://arxiv.org/abs/2610.11003 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_13c48b70cddc (Metraipolis archive dc_13c48b70cddc, sha256 b7bc3dc90c7a64187ccb0a5538299a5dceb593e6fb01182c13e0ba50367394aa)
BibTeX
@misc{dc13c48b70cddc,
title = {ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration — arXiv:2610.11003},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.11003},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_13c48b70cddc; sha256 b7bc3dc90c7a64187ccb0a5538299a5dceb593e6fb01182c13e0ba50367394aa},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.11003. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Accurate bone registration is essential for orthopedic surgical navigation and robotic assistance. In a common workflow, the surgeon needs to identify and probe a number of prescribed locations on the exposed bone surface to obtain data points for registration, which can be difficult and time-consuming under limited surgical exposure. Reducing the number of required points while providing clear probing guidance would ease the surgeon's acquisition task intra-operatively. We present ActiveReg, a closed-loop framework that recommends probing regions rather than individual points, allowing flexibility in the exact contact location. A D-optimal planner that takes into account the already acquired points and the uncertainty of current registration information helps achieve accurate registration with fewer points. An online assessment combines pre-update innovation consistency with uncertainty at predefined surgical task locations improves the reliability of completion decision, without requiring ground truth. Simulations across four anatomical scenarios demonstrated that ActiveReg can achieve competitive accuracy compared with baseline registration methods while using substantially fewer acquired points. Real phantom experiments with optical and electromagnetic tracking demonstrated comparable mean target registration error to the Gradient-SDF framework, using only 24-28 acquired points instead of 771-1263. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2610.11003 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T05:55:21.997Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).