Metraipolis › archive › dc_13a18bebc598
RAG-Based Auto-Configuration for Industrial Fieldbus Devices — arXiv:2608.08618
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.08618
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T08:50:49.854Z
- SHA-256 of the archived text
0d374f9e6931ed35a36e711483f9da13f7a623b60bbf554850340aebab4a1fcd- Stable URL of this page
https://metraipolis.com/documento/dc_13a18bebc598
How to cite
RAG-Based Auto-Configuration for Industrial Fieldbus Devices — arXiv:2608.08618 — arXiv (en), https://arxiv.org/abs/2608.08618 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_13a18bebc598 (Metraipolis archive dc_13a18bebc598, sha256 0d374f9e6931ed35a36e711483f9da13f7a623b60bbf554850340aebab4a1fcd)
BibTeX
@misc{dc13a18bebc598,
title = {RAG-Based Auto-Configuration for Industrial Fieldbus Devices — arXiv:2608.08618},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.08618},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_13a18bebc598; sha256 0d374f9e6931ed35a36e711483f9da13f7a623b60bbf554850340aebab4a1fcd},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.08618. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Industrial device commissioning requires engineers to manually extract hundreds of protocol-specific parameters from heterogeneous PDF manuals and transcribe them into supervisory control systems, a time-intensive, error-prone workflow. This paper presents SysName, a production-oriented pipeline that automates device configuration end-to-end for Modbus RTU, OPC-UA, Profibus DP, and CANopen. It builds a hybrid dense-sparse retrieval index augmented by an ontology graph derived from ECLASS, AAS, and SOSA/SSN, using a BGE-M3 encoder with a cross-encoder reranker to surface relevant manual passages. A local LLM (T=0.1) generates ontology-aligned JSON-LD configurations via protocol-specific prompts and a four-step repair pipeline. A two-stage abstention gate, combining a reranker-score threshold and an IRI resolution ratio, blocks unsafe LLM invocations and filters low-coverage configurations before SHACL validation. On a gold set of 28 field-level queries, the hybrid retriever reaches 0.96 HitRate@10, and the reranker raises MRR@10 from 0.56 to 0.63 with perfect score separation for abstention. The generator attains field-level F1=0.87 with exact match on 9 of 12 runs. End-to-end runs on an H100 GPU complete in 2.6-6.6s per device with zero unsafe writes and zero silent failures on a five-device benchmark; every unsuccessful run is flagged by abstention or deployment verification. Component-wise evaluation localises the single systematic failure to OPC-UA generation, invisible to end-to-end metrics alone. A case study commissions a physics-simulated Universal Robots UR5e robot from unmodified vendor documentation (254-page manual, 8-page register list, 496 chunks), reaching field-level F1=1.0 over three runs with read-back and joint-consistency verification. An ablation study and comparison with five industrial-LLM systems complete the analysis. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-11 in cs.CL). Categorie arXiv: Robotics (cs.RO) ; Artificial Intelligence (cs.AI); Computation and Language (cs.CL). Pagina del lavoro: https://arxiv.org/abs/2608.08618 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T08:49:41.988Z dalla pagina https://arxiv.org/catchup/cs.CL/2026-08-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).