Metraipolis › archive › dc_12b72d5415bb

Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEV — arXiv:2610.41054

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.41054
License (as archived)
CC0-1.0
Archived
2026-11-02T05:15:40.392Z
SHA-256 of the archived text
0a692d1464231b870b819dd4c8a57640e82f24c5b1a814524bba40e5f7bfce43
Stable URL of this page
https://metraipolis.com/documento/dc_12b72d5415bb

How to cite

Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEV — arXiv:2610.41054 — arXiv (en), https://arxiv.org/abs/2610.41054 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_12b72d5415bb (Metraipolis archive dc_12b72d5415bb, sha256 0a692d1464231b870b819dd4c8a57640e82f24c5b1a814524bba40e5f7bfce43)
BibTeX
@misc{dc12b72d5415bb,
  title = {Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEV — arXiv:2610.41054},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.41054},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_12b72d5415bb; sha256 0a692d1464231b870b819dd4c8a57640e82f24c5b1a814524bba40e5f7bfce43},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.41054. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Purpose: Patient-specific electro-anatomical models (EAMs) of the implanted cochlea are crucial for auditory nerve fiber simulation in cochlear implant (CI) programming and neural health estimation. Fitting an EAM to the stimulation current induced non-stimulating electrode voltage (SCINSEV) currently requires manual expert adjustment or exhaustive search over precomputed forward solutions, neither of which scales to routine clinical use. We present an automated optimization pipeline that fits patient specific EAMs in minutes. Methods: Four compartment tissue label maps (perilymph, soft tissue, modiolus, and bone) derived from postoperative CT were used to construct a finite difference forward model, fitted to the measured SCINSEV by Gaussian process Bayesian optimization. Three reductions cut fitting cost: a coarsened grid with trilinear injection and readout at sub-voxel contact positions; solving half the stimulating contacts and completing three quarters of the matrix by reciprocity; and a Jacobian-based identifiability analysis reducing four resistivities to two. Each reduction was validated separately against the measurement's reciprocity residual and the reproducibility of the fit. Results: Across 43 implanted ears, fitting took a median of 2.6 minutes per ear. Median SCINSEV RMSE on the reduced-resolution objective was 0.069 mV, against 0.084 mV for grid search at a matched evaluation budget. Against an exhaustive full-resolution grid search requiring a median of 9.1 hours per ear, the pipeline reached statistically indistinguishable fitting error roughly 210x faster. Conclusion: Patient-specific cochlear EAM fitting can be performed at clinically practical timescales without expert supervision, removing a major computational barrier to patient-specific cochlear implant programming and cochlear simulation.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.SP, nuovi lavori del giorno).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2610.41054 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-02T04:58:13.637Z dalla pagina https://arxiv.org/list/eess.SP/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).