Metraipolis › archive › dc_126ff5b84933

Composite Adaptive Higher-Order Control Barrier Functions for Joint Frequency-RoCoF Safety in Low-Inertia SIDS Microgrids — arXiv:2609.23123

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.23123
License (as archived)
CC0-1.0
Archived
2026-10-10T00:55:19.317Z
SHA-256 of the archived text
91f304a01c3dce08565593cd01662144e9d4e244518c4e9352baecd857c67b3f
Stable URL of this page
https://metraipolis.com/documento/dc_126ff5b84933

How to cite

Composite Adaptive Higher-Order Control Barrier Functions for Joint Frequency-RoCoF Safety in Low-Inertia SIDS Microgrids — arXiv:2609.23123 — arXiv (en), https://arxiv.org/abs/2609.23123 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_126ff5b84933 (Metraipolis archive dc_126ff5b84933, sha256 91f304a01c3dce08565593cd01662144e9d4e244518c4e9352baecd857c67b3f)
BibTeX
@misc{dc126ff5b84933,
  title = {Composite Adaptive Higher-Order Control Barrier Functions for Joint Frequency-RoCoF Safety in Low-Inertia SIDS Microgrids — arXiv:2609.23123},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.23123},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_126ff5b84933; sha256 91f304a01c3dce08565593cd01662144e9d4e244518c4e9352baecd857c67b3f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.23123. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Small Island Developing States (SIDS) face simultaneous frequency nadir and rate-of-change-of-frequency (RoCoF) violations under high renewable penetration. This paper proposes a \emph{Composite Adaptive Higher-Order Control Barrier Function} (CA-HOCBF) for BESS-coupled virtual synchronous generators that jointly enforces IEEE~1547 frequency ($\pm0.8$\,Hz) and ENTSO-E RoCoF ($\pm1$\,Hz/s) limits as hard safety constraints under parametric uncertainty. The method unifies three tools: (i)~a dual barrier architecture with a zeroing CBF for frequency and an algebraic RoCoF constraint with a robust inertia-floor fallback; (ii)~a composite energy function coupling logarithmic safety barriers with quadratic parameter and disturbance error terms, which drives safety-weighted adaptation; and (iii)~a disturbance observer integrated into the barrier dynamics. We prove that the closed-form QP is always feasible under a BESS capacity condition and, under explicitly stated assumptions, that the composite energy remains finite along trajectories, rendering the joint safe set forward invariant \emph{without requiring parameter convergence}. Simulation on a 10\,MW Caribbean microgrid ($H=2$\,s, 70\% renewables) shows the CA-HOCBF eliminates all frequency and RoCoF violations under a compound disturbance, achieving steady-state error of 0.001\,Hz and RoCoF of 0.50\,Hz/s, where fixed-gain VSGs suffer a 0.62\,Hz offset with 2.25\,Hz/s RoCoF violations.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-22 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY) ; Signal Processing (eess.SP); Optimization and Control (math.OC).
Pagina del lavoro: https://arxiv.org/abs/2609.23123 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).