Metraipolis › archive › dc_11f11a905552
When is a closed-form RGB->S/P ratio adequate? A hyperspectral characterization on natural scenes for mesopic display — arXiv:2609.24819
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.24819
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T22:06:40.754Z
- SHA-256 of the archived text
2ccda7f1af10f0af9b51eb51301dd7bcd9f18fa0efc5adb900369113bf7b26a6- Stable URL of this page
https://metraipolis.com/documento/dc_11f11a905552
How to cite
When is a closed-form RGB->S/P ratio adequate? A hyperspectral characterization on natural scenes for mesopic display — arXiv:2609.24819 — arXiv (en), https://arxiv.org/abs/2609.24819 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_11f11a905552 (Metraipolis archive dc_11f11a905552, sha256 2ccda7f1af10f0af9b51eb51301dd7bcd9f18fa0efc5adb900369113bf7b26a6)
BibTeX
@misc{dc11f11a905552,
title = {When is a closed-form RGB->S/P ratio adequate? A hyperspectral characterization on natural scenes for mesopic display — arXiv:2609.24819},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.24819},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_11f11a905552; sha256 2ccda7f1af10f0af9b51eb51301dd7bcd9f18fa0efc5adb900369113bf7b26a6},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.24819. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Mesopic and low-light display transforms require, as their driving signal, a per-pixel scotopic-to-photopic luminance ratio (S/P); the exact spectral S/P is unavailable for ordinary RGB content, so a low-cost closed form that estimates S/P from a linear-RGB triplet is used in its place. Such closed forms exist but have been characterized only on narrowband / LED sources, i.e. spectrally sparse spectra, where a relative error of ~41% has been reported for a three-channel projection. Display content, however, is natural and broadband. We ask whether the same closed form is adequate there, using per-pixel spectral S/P from hyperspectral imagery as ground truth. On a daylight radiance time-series, a six-scalar closed form (three photopic and three scotopic channel weights) reproduces spectral S/P with a median error of ~0.07 that is time-invariant once the RGB input is chromatically adapted to D65; evaluated in un-adapted sRGB the error instead carries a color-temperature tilt across illuminants (~0.19), so adaptation is the enabling step for this use case. The result generalizes to an independent fifty-scene set (pooled median 0.024; 45/50 scenes within a pre-registered 0.10 band), with the few exceedances concentrated in saturated, spectrally-peaky surfaces that approach the narrowband regime (floral close-ups in this set). The scotopic weight vector is shown to be primary-model dependent, but the value used here is corroborated by a primary-free XYZ projection, and the median error stays within the band across all principled coefficient choices. We do not claim observer-validated appearance fidelity or adequacy on narrowband sources; both are out of scope. Both outcomes follow from the same three-channel projection: it is overwhelmed by spectrally sparse inputs and adequate on spectrally smooth ones. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in cs.CV). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Graphics (cs.GR). Pagina del lavoro: https://arxiv.org/abs/2609.24819 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T21:45:21.158Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).