Metraipolis › archive › dc_11874a17f583
Heralded Non-Gaussian Squeezed-State Inputs for Parity-Detection SU(1,1) Interferometry — arXiv:2608.04476
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.04476
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T12:01:42.296Z
- SHA-256 of the archived text
552c9f1502336db55fecd5b25249ab31b7967552146944a505fb06f15b63f71e- Stable URL of this page
https://metraipolis.com/documento/dc_11874a17f583
How to cite
Heralded Non-Gaussian Squeezed-State Inputs for Parity-Detection SU(1,1) Interferometry — arXiv:2608.04476 — arXiv (en), https://arxiv.org/abs/2608.04476 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_11874a17f583 (Metraipolis archive dc_11874a17f583, sha256 552c9f1502336db55fecd5b25249ab31b7967552146944a505fb06f15b63f71e)
BibTeX
@misc{dc11874a17f583,
title = {Heralded Non-Gaussian Squeezed-State Inputs for Parity-Detection SU(1,1) Interferometry — arXiv:2608.04476},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.04476},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_11874a17f583; sha256 552c9f1502336db55fecd5b25249ab31b7967552146944a505fb06f15b63f71e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.04476. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Non-Gaussian operations can reshape the photon statistics of continuous-variable probes, but their metrological advantage is meaningful only when heralding probability and photon-number resources are counted consistently. We compare photon subtraction, photon addition, and photon catalysis as input-side heralding operations in a balanced SU(1,1) interferometer with parity detection. A unified finite-transmissivity map supplies closed conditional moments and the corresponding quantum Fisher information at arbitrary operation order; internal loss is absorbed into a single effective parity observable whose lossless limit recovers the ideal pulled-back measurement. At fixed preparation parameters, single-photon subtraction and addition improve the conditional phase information over the Gaussian reference across most of the high-transmissivity regime, while multi-photon catalysis opens useful low-transmissivity windows. However, when the coherent--squeezed allocation is independently optimized at fixed conditional-probe energy and fixed interferometer gain, the success-weighted Fisher information of all three non-Gaussian operations remains below the optimized Gaussian benchmark. This conclusion is subject to the tested constraints: single-photon operations, a coherent-plus-squeezed-vacuum Gaussian family, fixed gain, and parity readout. Photon catalysis separately generates a conditional branch with high local quantum Fisher information that dark-point parity extracts poorly, identifying a measurement mismatch rather than a state-preparation failure. The result draws a sharp boundary between conditional non-Gaussian enhancement and practically available precision under explicitly stated resource constraints. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-06 in quant-ph). Categorie arXiv: Quantum Physics (quant-ph). Pagina del lavoro: https://arxiv.org/abs/2608.04476 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T11:50:18.163Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-08-06?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).