Metraipolis › archive › dc_116faae7a9ce

Triaxial $μ$-PIC for resolving Multi-Hit Ambiguity — arXiv:2611.07638

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.07638
License (as archived)
CC0-1.0
Archived
2026-11-06T14:55:48.457Z
SHA-256 of the archived text
98e27a7467dbc767fb6bed6fd2249ff512846ccb5d7b3e40bb3f59e48344fb28
Stable URL of this page
https://metraipolis.com/documento/dc_116faae7a9ce

How to cite

Triaxial $μ$-PIC for resolving Multi-Hit Ambiguity — arXiv:2611.07638 — arXiv (en), https://arxiv.org/abs/2611.07638 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_116faae7a9ce (Metraipolis archive dc_116faae7a9ce, sha256 98e27a7467dbc767fb6bed6fd2249ff512846ccb5d7b3e40bb3f59e48344fb28)
BibTeX
@misc{dc116faae7a9ce,
  title = {Triaxial $μ$-PIC for resolving Multi-Hit Ambiguity — arXiv:2611.07638},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.07638},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_116faae7a9ce; sha256 98e27a7467dbc767fb6bed6fd2249ff512846ccb5d7b3e40bb3f59e48344fb28},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.07638. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The micro pixel chamber ($\mu$-PIC), a type of micro-pattern gaseous detectors (MPGD), features pixel electrodes structured similarly to a sliced proportional counter. Conventionally, $\mu$-PIC electrodes are connected to orthogonal strip electrodes to reduce the number of readout circuits; however, this configuration introduces multi-hit ambiguity when tracing winding tracks or during high-rate operations. A well-known solution to this problem is the adoption of an additional readout axis. To this end, we designed a new electrode structure using Garfield++ simulations and fabricated a triaxial $\mu$-PIC based on through-glass-via (TGV) technology. This triaxial $\mu$-PIC achieved a high gas gain of $1.1\times 10^4$ and the energy resolution of 22\% (FWHM) at 5.9~keV, Furthermore, the false-hit probability was less than 0.78\% at a 95\% confidence level for two clusters separated by a distance of over 3 mm, consistent with Garfield++ predictions. With this triaxial $\mu$-PIC, single avalanche signals are collected from three independent readout strip electrodes (the anode and two cathodes). The charge ratio among these electrodes remains nearly constant at anode:U-cathode:V-cathode=3:2:1. In addition, we successfully achieved an enhanced gain of $3.2\times 10^4$ without increasing the discharge risk by employing an alternative operation mode.

Tema degli esploratori: fisica e astronomia (elenco arXiv astro-ph.IM, nuovi lavori del giorno).
Categorie arXiv: Instrumentation and Detectors (physics.ins-det) ; Instrumentation and Methods for Astrophysics (astro-ph.IM); High Energy Physics - Experiment (hep-ex); Nuclear Experiment (nucl-ex).
Pagina del lavoro: https://arxiv.org/abs/2611.07638 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-06T14:38:21.045Z dalla pagina https://arxiv.org/list/astro-ph.IM/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).