Metraipolis › archive › dc_0f62afa191cc
Stochastic dose fluctuations in boron neutron capture therapy with heterogeneous boron distributions — arXiv:2611.06344
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.06344
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-05T18:34:06.266Z
- SHA-256 of the archived text
cbc402b1229f27e795cd5b211fa56cf20d964a01f704234af05286fc17b64c49- Stable URL of this page
https://metraipolis.com/documento/dc_0f62afa191cc
How to cite
Stochastic dose fluctuations in boron neutron capture therapy with heterogeneous boron distributions — arXiv:2611.06344 — arXiv (en), https://arxiv.org/abs/2611.06344 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0f62afa191cc (Metraipolis archive dc_0f62afa191cc, sha256 cbc402b1229f27e795cd5b211fa56cf20d964a01f704234af05286fc17b64c49)
BibTeX
@misc{dc0f62afa191cc,
title = {Stochastic dose fluctuations in boron neutron capture therapy with heterogeneous boron distributions — arXiv:2611.06344},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.06344},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0f62afa191cc; sha256 cbc402b1229f27e795cd5b211fa56cf20d964a01f704234af05286fc17b64c49},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.06344. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Dose fluctuations at the cellular scale in boron neutron capture therapy (BNCT) arise from stochastic neutron capture and spatially heterogeneous boron distributions. This study develops a stochastic framework combining energy-deposition responses from Geant4 simulations, a Poisson capture process, and spatially correlated lognormal boron fields to investigate nuclear dose variance and zero-hit probability. The results show that the variance contribution from stochastic neutron capture increases linearly with neutron fluence, whereas the contribution from boron heterogeneity increases quadratically. These distinct scaling behaviors produce a correlation-length-dependent crossover between the dominant sources of dose fluctuations. For a heterogeneity amplitude of $H=0.8$ and a correlation length of $\xi=3\,\mu\mathrm{m}$, the crossover occurs at approximately $1.50\times10^{12}\,\mathrm{cm}^{-2}$, while the ensemble relative dose variance approaches a plateau of $0.160$ at high fluence. Boron heterogeneity also increases the probability that a nucleus receives no energy deposition from alpha--lithium reaction products. At $\xi=6\,\mu\mathrm{m}$ and $\Phi_n=3\times10^{11}\,\mathrm{cm}^{-2}$, the zero-hit probability is $40.49\%$ higher than that for a homogeneous boron distribution with the same mean concentration. This study shows that spatial boron correlations and stochastic neutron capture influence nuclear dose fluctuations and zero-hit statistics beyond what can be characterized by mean boron concentration alone.
Tema degli esploratori: governance digitale e beni comuni (elenco arXiv physics.soc-ph, nuovi lavori del giorno).
Categorie arXiv: Physics and Society (physics.soc-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.06344 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-05T18:27:16.487Z dalla pagina https://arxiv.org/list/physics.soc-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).