Metraipolis › archive › dc_0eda1826983d

Structural validity and reliability of the patient experience measure: A new approach to assessing psychosocial experience of upper limb prosthesis users — Europe PMC PMID:34962943

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/34962943
DOI
10.1371/journal.pone.0261865
License (as archived)
CC0-1.0
Archived
2026-10-08T09:29:40.329Z
SHA-256 of the archived text
eb63c41b183f0ae31e25b08e7a3e243685633c09c50f147bf255233c98283dfd
Stable URL of this page
https://metraipolis.com/documento/dc_0eda1826983d

How to cite

Structural validity and reliability of the patient experience measure: A new approach to assessing psychosocial experience of upper limb prosthesis users — Europe PMC PMID:34962943 — Europe PMC (en), https://europepmc.org/article/MED/34962943 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0eda1826983d (Metraipolis archive dc_0eda1826983d, sha256 eb63c41b183f0ae31e25b08e7a3e243685633c09c50f147bf255233c98283dfd)
BibTeX
@misc{dc0eda1826983d,
  title = {Structural validity and reliability of the patient experience measure: A new approach to assessing psychosocial experience of upper limb prosthesis users — Europe PMC PMID:34962943},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/34962943},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0eda1826983d; sha256 eb63c41b183f0ae31e25b08e7a3e243685633c09c50f147bf255233c98283dfd},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/34962943. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Recent advances in upper limb prosthetics include sensory restoration techniques and osseointegration technology that introduce additional risks, higher costs, and longer periods of rehabilitation. To inform regulatory and clinical decision making, validated patient reported outcome measures are required to understand the relative benefits of these interventions. The Patient Experience Measure (PEM) was developed to quantify psychosocial outcomes for research studies on sensory-enabled upper limb prostheses. While the PEM was responsive to changes in prosthesis experience in prior studies, its psychometric properties had not been assessed. Here, the PEM was examined for structural validity and reliability across a large sample of people with upper limb loss (n = 677). The PEM was modified and tested in three phases: initial refinement and cognitive testing, pilot testing, and field testing. Exploratory factor analysis (EFA) was used to discover the underlying factor structure of the PEM items and confirmatory factor analysis (CFA) verified the structure. Rasch partial credit modeling evaluated monotonicity, fit, and magnitude of differential item functioning by age, sex, and prosthesis use for all scales. EFA resulted in a seven-factor solution that was reduced to the following six scales after CFA: social interaction, self-efficacy, embodiment, intuitiveness, wellbeing, and self-consciousness. After removal of two items during Rasch analyses, the overall model fit was acceptable (CFI = 0.973, TLI = 0.979, RMSEA = 0.038). The social interaction, self-efficacy and embodiment scales had strong person reliability (0.81, 0.80 and 0.77), Cronbach's alpha (0.90, 0.80 and 0.71), and intraclass correlation coefficients (0.82, 0.85 and 0.74), respectively. The large sample size and use of contemporary measurement methods enabled identification of unidimensional constructs, differential item functioning by participant characteristics, and the rank ordering of the difficulty of each item in the scales. The PEM enables quantification of critical psychosocial impacts of advanced prosthetic technologies and provides a rigorous foundation for future studies of clinical and prosthetic interventions.

Tema degli esploratori: matematica e informatica teorica (ricerca Europe PMC «linear algebra», solo open access).
Pubblicazione: PloS one, 2021 (prima pubblicazione 2021-12-28).
Identificativi: PMID 34962943 · PMCID PMC8714100 · DOI 10.1371/journal.pone.0261865.
Descrittori MeSH principali: Arm.
Pagina: https://europepmc.org/article/MED/34962943 — https://doi.org/10.1371/journal.pone.0261865. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-08T08:33:26.614Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.