Metraipolis › archive › dc_0eb5777c8487
uGMRT Polarization Observations with Walsh Modulation — arXiv:2610.20744
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.20744
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T10:49:57.520Z
- SHA-256 of the archived text
000a51e36e8b50a204c7a733c41d2d2087d670250cff1e0b77ab97e772ff7f3a- Stable URL of this page
https://metraipolis.com/documento/dc_0eb5777c8487
How to cite
uGMRT Polarization Observations with Walsh Modulation — arXiv:2610.20744 — arXiv (en), https://arxiv.org/abs/2610.20744 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0eb5777c8487 (Metraipolis archive dc_0eb5777c8487, sha256 000a51e36e8b50a204c7a733c41d2d2087d670250cff1e0b77ab97e772ff7f3a)
BibTeX
@misc{dc0eb5777c8487,
title = {uGMRT Polarization Observations with Walsh Modulation — arXiv:2610.20744},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.20744},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0eb5777c8487; sha256 000a51e36e8b50a204c7a733c41d2d2087d670250cff1e0b77ab97e772ff7f3a},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.20744. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
In this report, we discuss the performance of the Walsh phase-switching scheme for Band 4 (550-750 MHz) polarimetric observations with the upgraded GMRT (uGMRT). We have carried out test observations with the Walsh modulation enabled and disabled, using the polarized calibrator 3C138 as the target and unpolarized calibrator 3C147 for amplitude, phase and leakage calibration. The two Walsh datasets (ON & OFF) were processed using identical flagging, calibration, and imaging procedures. The Walsh ON data showed smoother leakage solutions and lower residual scatter in the Stokes I, Q, U data. The Walsh scheme also suppressed a fraction of anomalous data at the correlation stage, reducing the amount of subsequent flagging required during data processing. The final self-calibrated images obtained with Walsh ON showed improved image fidelity, lower r.m.s. noise, and reduced error in the fractional polarization of 3C138. However, the possibility that the Walsh scheme itself introduces spurious frequency-dependent structure into the Stokes Q and U signals remains and warrants closer investigation. Overall, these results demonstrate the potential of Walsh phase switching to mitigate instrumental cross-talk and improve the reliability of polarimetric measurements with the uGMRT. Tema degli esploratori: fisica e astronomia (elenco arXiv astro-ph.IM, nuovi lavori del giorno). Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM). Pagina del lavoro: https://arxiv.org/abs/2610.20744 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T08:58:07.323Z dalla pagina https://arxiv.org/list/astro-ph.IM/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).