Metraipolis › archive › dc_0e86ba52c388
PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed Laminography — arXiv:2611.00953
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00953
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:40:51.877Z
- SHA-256 of the archived text
b00d6d0a896ac7627a03b08170970ff3f5ebc945e3a5e2de8e5adb7789df04e5- Stable URL of this page
https://metraipolis.com/documento/dc_0e86ba52c388
How to cite
PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed Laminography — arXiv:2611.00953 — arXiv (en), https://arxiv.org/abs/2611.00953 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0e86ba52c388 (Metraipolis archive dc_0e86ba52c388, sha256 b00d6d0a896ac7627a03b08170970ff3f5ebc945e3a5e2de8e5adb7789df04e5)
BibTeX
@misc{dc0e86ba52c388,
title = {PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed Laminography — arXiv:2611.00953},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00953},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0e86ba52c388; sha256 b00d6d0a896ac7627a03b08170970ff3f5ebc945e3a5e2de8e5adb7789df04e5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00953. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cone-beam rotary computed laminography (CL) presents a viable alternative to cone-beam CT for imaging objects with high aspect ratios. Conventional reconstruction techniques, such as CL-FBP and CL-FDK, often yield suboptimal results charac?terized by pronounced superimposition artifacts, reduced contrast,and blurred edges, primarily due to their reliance on 1D row-wise filtering along detector rows. To address these limitations and improve reconstruction quality, we proposed a novel 2D directional filtered backprojection (DFBP) method based on the point spread function (PSF). First, an exact expression for the projection process is derived by establishing the relationship between a reconstructed pixel and its corresponding projection point on the detector. Second, a revised backprojection process incorporating two weighting factors is introduced to counteract the nonlinearity inherent in conventional backprojection, leading to a simplified PSF formulation. Third, to circumvent the computational burden of 3D image space filtering,an approximate method by linearizing the coordinate relationship in Fourier space under some assumptions is developed that transfers the 3D filtering operation to the 2D projection space. This approach facilitates the derivation of a formally simple yet effective 2D direc?tional filter, which integrates a 2D von Hann window and a 2D sinc window. Experimental results demonstrate that the proposed method produces reconstructions with superior contrast, sharper boundaries,and fewer superimposition artifacts compared to CL-FBP and CL?FDK. Moreover, it enables more accurate recovery of internal structures, such as bubble defects and electronic components. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.00953 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T11:06:37.462Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).