Metraipolis › archive › dc_0da36cc332f0
Identification of $dq$-Asymmetric Impedances as Complex Transfer Functions Using a Single Arbitrary Excitation — arXiv:2608.29740
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.29740
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T10:42:25.231Z
- SHA-256 of the archived text
2698069f41bd8ee645f843bc6e00124d7882914c054a8aee4f8e69de326db1fc- Stable URL of this page
https://metraipolis.com/documento/dc_0da36cc332f0
How to cite
Identification of $dq$-Asymmetric Impedances as Complex Transfer Functions Using a Single Arbitrary Excitation — arXiv:2608.29740 — arXiv (en), https://arxiv.org/abs/2608.29740 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0da36cc332f0 (Metraipolis archive dc_0da36cc332f0, sha256 2698069f41bd8ee645f843bc6e00124d7882914c054a8aee4f8e69de326db1fc)
BibTeX
@misc{dc0da36cc332f0,
title = {Identification of $dq$-Asymmetric Impedances as Complex Transfer Functions Using a Single Arbitrary Excitation — arXiv:2608.29740},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.29740},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0da36cc332f0; sha256 2698069f41bd8ee645f843bc6e00124d7882914c054a8aee4f8e69de326db1fc},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.29740. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cross-coupling between the $dq$ coordinates makes the identification of asymmetric grid impedances a challenging problem, particularly near the fundamental frequency where the asymmetric coupling is strongest. Existing schemes usually handle it either by perturbing the two coordinates sequentially, which lengthens the measurement, or by using a time-domain method with a global parametric model whose order must be tuned. This paper develops a single-shot active non-parametric frequency-domain method that avoids both. The equivalent impedance is parameterized by a pair of single-input single-output complex transfer functions. Each spectral line is fitted with a local rational model; the leakage and transient contributions are estimated, so that neither periodic steady-state excitation nor repeated excitation cycles are required. We give the exact finite-time discrete Fourier transform relation for the conjugate-coupled complex-signal model, and analyse the distortion that a stationary-frame filter placed ahead of the Park transform imposes on the identified pair. The method is validated on a controller hardware-in-the-loop platform against an analytically derived small-signal model, for a symmetric grid and for the same grid with an added grid-following converter that renders it asymmetric. Both complex transfer functions and all four real transfer functions of the $dq$ impedance are recovered over a wide band from a single one-second record of a random excitation, at 1 Hz resolution. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-01 in eess.SY). Categorie arXiv: Signal Processing (eess.SP) ; Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2608.29740 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T10:29:43.068Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).