Metraipolis › archive › dc_0ad130bd1183
A Sensitivity-based Framework for Calibrating Coupled Ordinary Differential Equations under Model Discrepancy — arXiv:2610.09261
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.09261
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T12:40:18.118Z
- SHA-256 of the archived text
eac0672a820ed3c42d3c1cc2c9625ad9256ff91d756f1a8451d36f2753c936d5- Stable URL of this page
https://metraipolis.com/documento/dc_0ad130bd1183
How to cite
A Sensitivity-based Framework for Calibrating Coupled Ordinary Differential Equations under Model Discrepancy — arXiv:2610.09261 — arXiv (en), https://arxiv.org/abs/2610.09261 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_0ad130bd1183 (Metraipolis archive dc_0ad130bd1183, sha256 eac0672a820ed3c42d3c1cc2c9625ad9256ff91d756f1a8451d36f2753c936d5)
BibTeX
@misc{dc0ad130bd1183,
title = {A Sensitivity-based Framework for Calibrating Coupled Ordinary Differential Equations under Model Discrepancy — arXiv:2610.09261},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.09261},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_0ad130bd1183; sha256 eac0672a820ed3c42d3c1cc2c9625ad9256ff91d756f1a8451d36f2753c936d5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.09261. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Coupled systems of ordinary differential equations (ODEs) are widely used to model complex physical and biological processes. In these applications, ODE model parameters must be calibrated to field data to enable prediction and parameter inference. In practice, the governing ODEs are an imperfect approximation to the true system, leading to non-negligible model discrepancy that must be incorporated to avoid biased parameter estimates. However, it is well known that highly flexible discrepancy models can confound discrepancy and simulator parameters, leading to poor identifiability. As a result, practitioners often must impose problem-specific prior constraints to adequately regularize the discrepancy, which can be challenging and cumbersome. In this work, we propose a novel calibration framework for coupled, multi-output ODE systems that enforces automatic, model-structural constraints on the discrepancy, improving identifiability without requiring application-specific discrepancy priors. Forward-model gradients are computed via sensitivity equations, solved jointly with the ODE system as a coupled initial value problem. Posterior inference is performed using an adaptive Metropolis-within-Gibbs sampler tailored to the resulting constrained posterior. We demonstrate the approach on three model systems: a mass-spring oscillator, a model of infectious disease spread, and a neuron firing model. We show that our method leads to improved parameter inference and predictive accuracy compared to standard calibration approaches. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv stat.AP, nuovi lavori del giorno). Categorie arXiv: Applications (stat.AP) ; Optimization and Control (math.OC). Pagina del lavoro: https://arxiv.org/abs/2610.09261 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T12:15:30.218Z dalla pagina https://arxiv.org/list/stat.AP/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).